Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2006935
Status: Active
Facility Name: Circle K #6724
Address: 1117 Maple
Lisle, IL 60532
County: Du Page
Property Parcel: 08-10-409-007
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01783
Green Tag Issue Date: 1/30/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd.
Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/30/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 1/7/2010
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1970
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
07-0039 1/16/2007 Removal Log 01426-2006REM
95-2535 12/14/1995 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
05-1037 Eligible 12/19/2005 1/30/2006 $10,000
07-0039 Eligible 4/2/2007 4/12/2007 $10,000
87-0737 Eligible 6/15/2009 6/18/2009 $50,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/16/2007
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/25/1981 Red Tag Issue Date:
Last Used Date: 6/30/2004 Fee Due: $0.00
Product Date: 11/25/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/16/2007
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/25/1981 Red Tag Issue Date:
Last Used Date: 1/5/2007 Fee Due: $0.00
Product Date: 11/25/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/16/2007
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/25/1981 Red Tag Issue Date:
Last Used Date: 1/5/2007 Fee Due: $0.00
Product Date: 11/25/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/14/1995
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 11/15/1995 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/2007 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 3/14/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/7/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/10/2024 9/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/10/2024 9/10/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/10/2024 9/10/2025
Overfill Prev Device Overfill Drop Tube Valve 10/31/2022 10/31/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 1/23/2024 1/23/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 1/2/2020 1/2/2021
Leak Detect - Piping Non-Discriminating Sump Sensor 12/8/2020 12/8/2021
Leak Detect - Piping Non-Discriminating Sump Sensor 11/15/2021 11/15/2022
Leak Detect - Piping Sump Sensor with positive shutdown 9/10/2024 9/10/2025
Spill Contain Device Single Wall Spill Bucket 1/23/2024 1/23/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/10/2024



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/2007 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 3/14/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/7/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/10/2024 9/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/10/2024 9/10/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/10/2024 9/10/2025
Overfill Prev Device Overfill Drop Tube Valve 10/31/2022 10/31/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 1/23/2024 1/23/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 10/17/2022 10/17/2023
Leak Detect - Piping Sump Sensor with positive shutdown 1/30/2023 1/30/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/10/2024 9/10/2025
Spill Contain Device Single Wall Spill Bucket 1/23/2024 1/23/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/10/2024



Tank Number 7

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/2007 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 3/14/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/7/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/10/2024 9/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/10/2024 9/10/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/10/2024 9/10/2025
Overfill Prev Device Overfill Drop Tube Valve 10/31/2022 10/31/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025
Spill Contain Device Single Wall Spill Bucket 1/23/2024 1/23/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 9/10/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/23/2024 1/23/2027
Leak Detect - Piping Sump Sensor 9/10/2024 9/10/2025

MFD Motorfuel Dispensing Forms

No Forms Found