Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2006913
Status: Active
Facility Name: Circle K #6740
Address: 2635 West 87th Street Evergreen Park, IL 60619
County: Cook
Property Parcel: 24-01-202-009-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001345
Green Tag Issue Date: 12/5/2024
Green Tag Expire Date: 12/31/2026
MFD Type: N/A

Owner Details

Owner Name: RDK Ventures LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/15/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures LLC Current Owner 1/15/2010
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1971
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00196-2026UPG Upgrade Approved / Issued 2/19/2026 2/19/2026 8/19/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020260625 (Pending)    Issue Date: 3/12/2026    Expiration Date: 5/11/2026    View NOV Form

Tanks Violations
1, 2, 3 Dispensers - hoses cracked, split or worn and require replacement - Crack/cut in hose. Replace.
1, 3 Install or replace lockable fill pipe caps. - Regular close to the street is missing the fill cap and the premium fill cap is missing the gasket. Repair/Replace
Facility Missing list of designated Class A/B & C Operators - Can be found at https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/listofdesignatedoperators.pdf
1, 2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3 Tank monitor does not appear to function properly and requires maintenance. - Indicator light(s) on panel of Veeder-Root ATG is/are not functional. Replace as necessary to provide proper operation. (Green light is out. All lights need to be working)
1, 2, 3 Water in containment without required sensors – install cathodic protection on all exposed steel piping or make containment watertight. By 10/13/28, all containments must be watertight and any CP installed in containments must be removed. - Disp. 11/12. Will need documentation showing that containment was fixed.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-0955 Eligible 10/1/2008 10/14/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/10/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 2/10/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/10/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/11/2024 3/11/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/28/2025 7/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/28/2025 7/28/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/8/2024 8/8/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/28/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/10/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 2/10/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/10/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/11/2024 3/11/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/28/2025 7/28/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/8/2024 8/8/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/28/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 10/18/2022



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/10/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 2/10/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/10/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/11/2024 3/11/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/28/2025 7/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/28/2025 7/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/8/2024 8/8/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 8/8/2024 8/8/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/28/2025



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/1/1986
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 10/26/1986 Fee Due:
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/27/1986
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 10/26/1986 Fee Due:
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/27/1986
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 10/26/1986 Fee Due:
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/6/2026 5/6/2029
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found