Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2005467
Status: Active
Facility Name: Little Company of Mary Hospital
Address: 2800 W. 95th Street Evergreen Park, IL 60805
County: Cook
Property Parcel: 24-01-328-005-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: Z002657
Green Tag Issue Date: 10/28/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Little Company of Mary Hospital
Owner Address: 2800 W. 95th Street Evergreen Park, IL 60805
Owner Status: Current Owner
Purchase Date: 2/2/2012
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/19/2026

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009250 Little Company of Mary Hospital Current Owner 2/2/2012

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252418 (Pending)    Issue Date: 9/17/2025    Expiration Date: 11/16/2025    View NOV Form

Tanks Violations
10 Line leak detection equipment in alarm or failed test, must repair or replace. - Tank 10 West STP Sump sensor failed inspection on 6/6/2025. Repair/Replace and retest.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
10-0972 9/1/2010 Removal Log 00375-2010REM
10-0972 8/31/2010 Removal Log 00375-2010REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/1/1988
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 43 Abandoned Date: 10/1/1976
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1976 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8200 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/2010
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1958 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1958

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Tank Impressed Current Cathodic Protection
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/31/2010
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 6/6/2025 6/6/2026
Overfill Prev Device Overfill Alarm 7/8/2024 7/8/2027
Piping Flexible Double Wall OmegaFlex DoubleTrac N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/30/2023 5/30/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OmegaFlex DoubleTrac Precision Test (Piping) Pass 9/19/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/14/2024



Tank Number 7

Capacity: 10000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/2/1992 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 8200 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/2/1992 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 20000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 6/2/1992 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 35000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/24/2012 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 2/2/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/6/2025 6/6/2026
Overfill Prev Device Overfill Alarm 5/30/2023 5/30/2026
Overfill Prev Device Overfill Drop Tube Valve 5/30/2023 5/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor
Leak Detect - Piping Sump Sensor 9/17/2024 6/6/2025
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2022 7/22/2023
Leak Detect - Piping Sump Sensor 6/6/2025 6/6/2026
Spill Contain Device Single Wall Spill Bucket 5/30/2023 5/30/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 9/17/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/11/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/12/2024



Tank Number 11

Capacity: 35000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/24/2012 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 2/2/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/21/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/6/2025 6/6/2026
Overfill Prev Device Overfill Alarm 5/30/2023 5/30/2026
Overfill Prev Device Overfill Drop Tube Valve 5/30/2023 5/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2022 7/22/2023
Leak Detect - Piping Sump Sensor 6/6/2025 6/6/2026
Piping Single Wall STP/Tanktop Sump 5/30/2023 5/30/2026
Leak Detect - Piping Sump Sensor 6/14/2024 6/14/2025
Leak Detect - Piping Sump Sensor 6/6/2025 6/6/2026
Spill Contain Device Single Wall Spill Bucket 5/30/2023 5/30/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 9/17/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/11/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/19/2024

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found