Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2003068
Status: Active
Facility Name: First Student, Inc. #12910
Address: 10000 W. 167th St. Orland Park, IL 604675420
County: Cook
Property Parcel: 27-21-402-001-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: Z001289
Green Tag Issue Date: 5/14/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Fleet

Owner Details

Owner Name: First Student, Inc.
Owner Address: 191 Rosa Parks Street 8th Floor Cincinnati, OH 45202
Owner Status: Current Owner
Purchase Date: 10/8/2025
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030276 First Student, Inc. Current Owner 10/8/2025
U0041947 NHNR Hold Co 44, LLC Former Owner 6/9/2026
U0013599 Consolidated High School District 230 Former Owner 12/31/1967
U0038028 Cook-Illinois Corp. Former Owner
U0023230 Liberty School Bus Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261801 (Referred to Legal)    Issue Date: 7/14/2026    Expiration Date: 9/12/2026    View NOV Form

Tanks Violations
Facility Financial responsibility must be reported yearly - The form can be found at: https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility. (Submit this form after the change of ownership notification form has been approved.)
Facility Submit Notification Form for Ownership Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. Select “New Owner” as the type of notification form. ( Make sure you write down the access Code that is given to you when you start the notification form.) Owner has to match as it appears on the deed.
2 Water in containment without required sensors – install cathodic protection on all exposed steel piping or make containment watertight. By 10/13/28, all containments must be watertight and any CP installed in containments must be removed. - Regular STP has water.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-0389 3/7/2000 Removal Log 00206-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
00-0389 Eligible 5/26/2000 6/21/2000 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/14/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date: 10/5/2026
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 11/5/2025 11/5/2030
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 7/31/2026 7/31/2027
Overfill Prev Device Overfill Alarm 4/24/2025 4/24/2028
Overfill Prev Device Overfill Drop Tube Valve 9/10/2025 9/10/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/24/2025 4/24/2028
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 11/6/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/14/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date: 10/5/2026
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 11/5/2025 11/5/2030
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 7/31/2026 7/31/2027
Overfill Prev Device Overfill Alarm 4/24/2025 4/24/2028
Overfill Prev Device Overfill Drop Tube Valve 4/24/2025 4/24/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/24/2025 4/24/2028
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 11/6/2025



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/7/2000
OSFM First Notify Date: 3/14/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/21/1998 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found