Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2002931
Status: Closed
Facility Name: Bernick Transport
Address: 700 Larsen Lane
Bensenville, IL 60106
County: Du Page
Property Parcel: 03-11-200-048-0000
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002788
Green Tag Issue Date: 9/26/2023
Green Tag Expiration Date: 8/27/2024

Owner Details

Owner Name: CPI/DSP Larsen Lane Owner, LLC
Owner Address: 350 W. Hubbard Street
Suite 605
Chicago, IL 60654
Owner Status: Current Owner
Purchase Date: 9/19/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/18/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 9/26/2023 12/31/2025
Self Service 10/12/2007 12/31/2009

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041248 CPI/DSP Larsen Lane Owner, LLC Current Owner 9/19/2023
U0037098 Tri Air Transportation Former Owner 1/1/2013
U0008929 Larsen Leasing, Ltd. Former Owner 1/1/2013

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-0902 5/15/2000 Removal Log 00673-2000REM
04-0170 3/30/2004 Removal Log 04202-2004REM
2024-0577 8/22/2024 Removal Log 00902-2024REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-0170 Eligible 5/3/2004 5/3/2004 $10,000
20240577 Eligible 1/13/2025 1/16/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/30/2004
OSFM First Notify Date: 3/10/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 2/1/2004 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/15/2000
OSFM First Notify Date: 3/10/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 8/15/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/2024
OSFM First Notify Date: 3/10/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/4/2023 4/4/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/4/2023 4/4/2024
Overfill Prev Device Overfill Drop Tube Valve 6/3/2022 6/3/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/25/2022 4/25/2025
Tank Jacketed Steel Single Wall Total Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/4/2023

Dispenser Information



Name\ID 20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found