Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2001818
Status: Active
Facility Name: Prairie State College
Address: 202 S Halsted St, Building K Chicago Heights, IL 60411
County: Cook
Property Parcel:
Facility Type: School/College
Owner Type: Private
Green Tag Decal: Z001322
Green Tag Issue Date: 8/15/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Fleet

Owner Details

Owner Name: Prairie State College
Owner Address: 202 S Halsted St, Building K Chicago Heights, IL 60411
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/18/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0012112 Prairie State College Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260591 (Referred to Legal)    Issue Date: 3/6/2026    Expiration Date: 5/5/2026    View NOV Form

Tanks Violations
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/30-day-walkthrough-inspection-report.pdf
Facility Submit Notification Form for Facility Information Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm.

NOV Number: E0020261296 (Pending)    Issue Date: 5/18/2026    Expiration Date: 5/18/2026    View NOV Form

Tanks Violations
Facility No A/B operator designated for facility: attended or unattended/unmanned.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/12/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 2/1/1981 Red Tag Issue Date: 5/18/2026
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 6/24/2025 6/24/2026
Overfill Prev Device Overfill Drop Tube Valve 6/12/2024 6/12/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 6/12/2024 6/12/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/16/1998
OSFM First Notify Date: 2/12/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1997 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 250 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/12/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found