Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1047505
Status: Active
Facility Name: Michlig Energy
Address: 20805 IL Hwy 40 Sheffield, IL 61361
County: Bureau
Property Parcel: 08-21-200-003
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: AA03631
Green Tag Issue Date: 4/28/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Michlig Agricenter, Inc.
Owner Address: 105 1St St Manlius, IL 61338
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/14/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 4/28/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0010230 Michlig Agricenter, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/13/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 10/27/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/27/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/11/2025 2/11/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/10/2025 2/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/11/2025 2/11/2026
Overfill Prev Device Overfill Alarm 12/1/2022 12/1/2025
Overfill Prev Device Overfill Drop Tube Valve 12/1/2022 12/1/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 11/3/2022 11/3/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/11/2025 2/11/2026
Spill Contain Device Double Wall Spill Bucket 11/3/2022 11/3/2025
Tank Composite Double Wall Permatank N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 11/30/2022
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 11/30/2022



Tank Number 2

Capacity: 4000 Petroleum Use: None
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/13/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 10/27/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/27/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/11/2025 2/11/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/10/2025 2/10/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/11/2025 2/11/2026
Overfill Prev Device Overfill Alarm 12/1/2022 12/1/2025
Overfill Prev Device Overfill Drop Tube Valve 12/1/2022 12/1/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 11/3/2022 11/3/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/11/2025 2/11/2026
Spill Contain Device Double Wall Spill Bucket 11/3/2022 11/3/2025
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 11/30/2022
Tank Composite Double Wall Permatank Precision Test (Tank) Pass 12/5/2022

Dispenser Information



Name\ID 1M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/3/2022 11/3/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/11/2025 2/11/2026



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/3/2022 11/3/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/11/2025 2/11/2026



Name\ID 2M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/3/2022 11/3/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/11/2025 2/11/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1047505 Michlig Energy Sheffield 12/21/2022 Letter Form