Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1047449
Status: Active
Facility Name: QuiK Trip #7203
Address: 1320 May Rd. Peru, IL 61354
County: LaSalle
Property Parcel: 17-04-107-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003400
Green Tag Issue Date: 6/13/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: QuikTrip Corporation
Owner Address: 4705 South 129th East Ave. Tulsa, OK 74134
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/11/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/5/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034559 QuikTrip Corporation, Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251780 (Pending)    Issue Date: 7/15/2025    Expiration Date: 9/13/2025    View NOV Form

Tanks Violations
3, 6, 7, 9, 10 Annual electronic line leak detector test not completed.
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Document that emergency shut-off (shear valves) are in proper working order
1, 2, 3, 4, 5, 7 Line interstitial sensor functional test not accomplished (Required annually). - Tank top sumps as indicated and dispensers 1/2, 3/4, 5/6, 7/8, 9/10, 11/12, 15/16, 17/18 do not have current test results for 2025.
7, 8, 9, 10 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed. Sensors are not in the lowest point of the UDC at diesel pumps 4, 5,6 and 7. All have a notable amount of liquid present.
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing copies of current testing certificates for operator training - AB Certificate is missing for the individual conducting the 30 day walkthrough inspection. Last documented inspection was April 2025.
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3, 4, 5 Tank interstitial sensor functional test not accomplished (Required annually).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/12/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/11/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/28/2025 5/28/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Double Wall Spill Bucket 11/29/2022 11/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 4/14/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/8/2023



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/12/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/11/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Double Wall Spill Bucket 11/29/2022 11/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 4/14/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/8/2023



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/12/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/11/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/14/2025 4/14/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Double Wall Spill Bucket 11/29/2022 11/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 4/15/2024
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/8/2023



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/12/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/11/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/28/2025 5/28/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Double Wall Spill Bucket 11/29/2022 11/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 7/23/2025
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 4/15/2024
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/7/2023



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/12/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/11/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/28/2025 5/28/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 7/23/2025 7/23/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025
Piping Single Wall Transition Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Double Wall Spill Bucket 11/29/2022 11/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 4/14/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/7/2023



Tank Number 6

Capacity: 18000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/28/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/9/2025 6/9/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Spill Contain Device Double Wall Spill Bucket 12/7/2022 12/7/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 6/9/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/7/2023



Tank Number 7

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/28/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/9/2025 6/9/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Single Wall Transition Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Single Wall Transition Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Single Wall Transition Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026
Spill Contain Device Double Wall Spill Bucket 12/7/2022 12/7/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/1/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 6/9/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/6/2023



Tank Number 8

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/28/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/9/2025 6/9/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/9/2025 6/9/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Single Wall Transition Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Spill Contain Device Double Wall Spill Bucket 12/7/2022 12/7/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/1/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 6/9/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/6/2023



Tank Number 9

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/28/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/9/2025 6/9/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 5/9/2023 5/9/2026
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Spill Contain Device Double Wall Spill Bucket 12/7/2022 12/7/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 6/9/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/7/2023



Tank Number 10

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/17/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/28/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/23/2025 7/23/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/9/2025 6/9/2026
Overfill Prev Device Overfill Alarm 5/9/2023 5/9/2026
Overfill Prev Device Overfill Drop Tube Valve 1/16/2025 1/16/2028
Piping Blending Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026
Spill Contain Device Double Wall Spill Bucket 12/7/2022 12/7/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 5/9/2023
Piping Flexible Single Wall Piping Precision Test (Piping) Pass 6/9/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 5/7/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 1D/2D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 2D/3D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 3D/4D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 4D/5D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 5D/6D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 6D/7D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026



Name\ID 7D/8D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/7/2022 12/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/9/2025 6/9/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/29/2022 11/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/23/2025 7/23/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1047449 QuiK Trip #7203 Peru 05/22/2023 Letter Form