Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1045446
Status: Active
Facility Name: Mustang Corner, LLC
Address: 401 Tech Dr. Morrison, IL 61270
County: Whiteside
Property Parcel: 09-19-251-007
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000409
Green Tag Issue Date: 6/18/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Coz-E Corner, Inc.
Owner Address: 401 Tech Dr. Morrison, IL 61270
Owner Status: Current Owner
Purchase Date: 5/9/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/22/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038737 Coz-E Corner, Inc. Current Owner 5/9/2017
U0036987 Cozzie, Mike Former Owner 1/21/2014

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261001 (Pending)    Issue Date: 4/15/2026    Expiration Date: 6/14/2026    View NOV Form

Tanks Violations
Facility Fire Extinguishers - Past due for annual testing - Test date 12/2024

NOV Number: E0020261002 (Pending)    Issue Date: 4/15/2026    Expiration Date: 6/14/2026    View NOV Form

Tanks Violations
1, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - STP's

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/2014 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 9/26/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/26/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 with SCALD 4/10/2026 4/10/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/10/2026 4/10/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 4/14/2025 4/14/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/14/2025 4/14/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2026 4/10/2027
Spill Contain Device Single Wall Spill Bucket 4/14/2025 4/14/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/10/2026



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/2014 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 9/26/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/26/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 with SCALD 4/10/2026 4/10/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/10/2026 4/10/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 4/14/2025 4/14/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/14/2025 4/14/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2026 4/10/2027
Spill Contain Device Single Wall Spill Bucket 4/14/2025 4/14/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/10/2026



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/2014 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 9/26/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/26/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2026 4/10/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 with SCALD 4/10/2026 4/10/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/10/2026 4/10/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 4/14/2025 4/14/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/14/2025 4/14/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2026 4/10/2027
Spill Contain Device Single Wall Spill Bucket 4/14/2025 4/14/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 4/10/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/14/2025 4/14/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2026 4/10/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/14/2025 4/14/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2026 4/10/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/14/2025 4/14/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2026 4/10/2027

MFD Motorfuel Dispensing Forms

No Forms Found