Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1033461
Status: Active
Facility Name: South West Ave Mobil Mart
Address: 1730 S West Ave Freeport, IL 60132
County: Stephenson
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000847
Green Tag Issue Date: 3/4/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Kelley Williamson Company
Owner Address: 1132 Harrison Avenue Rockford, IL 61104
Owner Status: Current Owner
Purchase Date: 4/10/1995
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/26/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008336 Kelley Williamson Company, Current Owner 4/10/1995

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261139 (Pending)    Issue Date: 4/29/2026    Expiration Date: 6/28/2026    View NOV Form

Tanks Violations
1, 2, 3 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - Triennial testing for qualifying STP piping containment sump(s) not completed. Triennial testing for qualifying dispenser containment sump(s) not completed.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/17/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/20/2026 4/20/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/20/2026 4/20/2027
Overfill Prev Device Overfill Alarm 4/8/2024 4/8/2027
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 5/19/2026 5/19/2029
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 8/26/2022 8/26/2023
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027
Spill Contain Device Single Wall Spill Bucket 5/19/2026 5/19/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/16/2022
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 4/8/2024
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 8/26/2022



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/17/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/20/2026 4/20/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/20/2026 4/20/2027
Overfill Prev Device Overfill Alarm 4/8/2024 4/8/2027
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 5/19/2026 5/19/2029
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 8/26/2022 8/26/2023
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027
Spill Contain Device Single Wall Spill Bucket 5/19/2026 5/19/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/16/2022
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 8/26/2022
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 4/8/2024



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/17/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/20/2026 4/20/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/20/2026 4/20/2027
Overfill Prev Device Overfill Alarm 4/8/2024 4/8/2027
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 5/19/2026 5/19/2029
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 8/26/2022 8/26/2023
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027
Spill Contain Device Single Wall Spill Bucket 5/19/2026 5/19/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/16/2022
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 4/8/2024
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test (Piping) Pass 8/26/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/19/2026 5/19/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/19/2026 5/19/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/19/2026 5/19/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/19/2026 5/19/2029
Leak Detect - Piping Sump Sensor with positive shutdown 4/20/2026 4/20/2027

MFD Motorfuel Dispensing Forms

No Forms Found