Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1032717
Status: Active
Facility Name: Penske Truck Leasing
Address: 4617 Sandy Hollow Road
Rockford, IL 61109
County: Winnebago
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: AA04139
Green Tag Issue Date: 1/21/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Penske Truck Leasing Co., LP
Owner Address: Route 10 Green Hills
Reading, PA 19603
Owner Status: Current Owner
Purchase Date: 3/1/2001
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/21/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0006765 Penske Truck Leasing Co., LP Current Owner 3/1/2001
U0020478 Rollins Leasing Corp Former Owner 1/12/1994

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/13/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/13/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/30/2024 7/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/30/2024 7/30/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Drop Tube Valve 9/2/2022 9/2/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 12/21/2022 12/21/2025
Leak Detect - Piping Sump Sensor 7/30/2024 7/30/2025
Piping Single Wall Transition Sump 5/9/2023 5/9/2026
Leak Detect - Piping Sump Sensor 7/30/2024 7/30/2025
Spill Contain Device Single Wall Spill Bucket 8/2/2023 8/2/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 7/30/2024

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Leak Detect - Piping Sump Sensor with positive shutdown 7/30/2024 7/30/2025



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms