Facility Details
Facility Number:
1027978
Status:
Closed
Facility Name:
Circle K #4701323
Address:
6950 E. Riverside Drive Loves Park, IL 61111
County:
Winnebago
Property Parcel:
12-03-278-006
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Y001278
Green Tag Issue Date:
3/23/2023
Green Tag Expiration Date:
10/1/2025
Owner Details
Owner Name:
Mac's Convenience Stores, LLC
Owner Address:
1100 Situs Court, Suite 100 Raleigh, NC 27606
Owner Status:
Current Owner
Purchase Date:
12/30/2020
Type of Financial Responsibility:
Guarantee
Financial Responsibility Reporting Due Date:
1/26/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
3/23/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0030949
Mac's Convenience Stores, LLC
Current Owner
12/30/2020
U0030258
Kooshtard Property III, LLC
Former Owner
6/21/2001
U0023515
Johnson Oil Company, L.L.C.
Former Owner
12/10/1999
U0000552
BP Products North America, Inc.
Former Owner
1/1/1991
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2025-0754
9/30/2025
Removal Log
00904-2025REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
14-0745
Eligible
10/20/2014
12/16/2014
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
None
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/30/2025
OSFM
First Notify Date:
11/20/1991
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
1/1/1991
Red Tag Issue Date:
Last Used Date:
5/22/2025
Fee Due:
$0.00
Product Date:
1/10/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
2/5/2022
2/5/2025
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
11/6/2024
11/6/2025
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
11/6/2024
11/6/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/4/2023
12/4/2026
Piping
Fiberglass Single Wall Piping A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/23/2021
2/23/2024
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping A.O. Smith
Precision Test (Piping)
Pass
11/6/2024
Tank Number 2
Capacity:
12000
Petroleum Use:
None
Product:
Gasoline - Mid-grade
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/30/2025
OSFM
First Notify Date:
11/20/1991
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
1/1/1991
Red Tag Issue Date:
Last Used Date:
5/22/2025
Fee Due:
$0.00
Product Date:
1/10/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
2/5/2022
2/5/2025
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
11/6/2024
11/6/2025
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
11/6/2024
11/6/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/4/2023
12/4/2026
Piping
Fiberglass Single Wall Piping A.O. Smith
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/23/2021
2/23/2024
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping A.O. Smith
Precision Test (Piping)
Pass
11/6/2024
Tank Number 3
Capacity:
12000
Petroleum Use:
None
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/30/2025
OSFM
First Notify Date:
11/20/1991
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
1/1/1991
Red Tag Issue Date:
Last Used Date:
5/22/2025
Fee Due:
$0.00
Product Date:
1/10/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
2/5/2022
2/5/2025
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
11/6/2024
11/6/2025
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
11/6/2024
11/6/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/4/2023
12/4/2026
Piping
Fiberglass Single Wall Piping A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/23/2021
2/23/2024
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping A.O. Smith
Precision Test (Piping)
Pass
11/6/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found