Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1027498
Status: Active
Facility Name: Circle K #1436
Address: 2210 Locust Sterling, IL 61081
County: Whiteside
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000469
Green Tag Issue Date: 7/10/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100 Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 10/10/2014
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/10/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 10/10/2014
U0018041 Tri Star Marketing, Inc. Former Owner 1/1/1990
U0013268 Tri-Star Marketing, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251912 (Pending)    Issue Date: 7/29/2025    Expiration Date: 9/27/2025    View NOV Form

Tanks Violations
1, 2, 3 Annual leak detection certification not completed (Required annually). - Failed testing 2/27/2025- repair or replace & submit passing test rewsults to OSFM
1, 2, 3 Line interstitial sensor functional test not accomplished (Required annually). - Past due 3/18/2025
1, 2, 3 Mechanical line leak detector requires annual functional test. - Past due 3/18/2025

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/18/2024 2/27/2025
Overfill Prev Device Overfill Drop Tube Valve 2/27/2025 2/27/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Double Wall Spill Bucket 3/18/2024 3/18/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/18/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/13/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/18/2024 2/27/2025
Overfill Prev Device Overfill Drop Tube Valve 2/27/2025 2/27/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Double Wall Spill Bucket 3/18/2024 3/18/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/18/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/18/2024



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/18/2024 2/27/2025
Overfill Prev Device Overfill Drop Tube Valve 2/27/2025 2/27/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Double Wall Spill Bucket 3/18/2024 3/18/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/18/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/13/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2023 4/4/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025

MFD Motorfuel Dispensing Forms

No Forms Found