Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1026670
Status: Active
Facility Name: Express Lane Gas & Food Mart Inc
Address: 1218 Palmyra
Dixon, IL 61021
County: Lee
Property Parcel: 07-02-31-455-023
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00703
Green Tag Issue Date: 3/4/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Arthur J. Johnson Family Limited Partnership
Owner Address: 1305 12th Avenue
Rock Falls, IL 61071
Owner Status: Current Owner
Purchase Date: 10/6/2006
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 9/22/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/4/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040750 Arthur J. Johnson Family Limited Partnership Current Owner 10/6/2006
U0008040 Johnson Oil Company Former Owner 10/1/1989

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2024-0255 4/9/2024 Removal Log 00351-2024REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20240255 Eligible 4/23/2024 4/25/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/9/2024
OSFM First Notify Date: 11/27/1989 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 8/8/2023 8/8/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2024 2/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/3/2024 2/3/2025
Overfill Prev Device Overfill Alarm 2/3/2024 2/3/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/28/2022 10/28/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/28/2022
Tank STIP3 Single Wall Precision Test (Tank) Pass 3/27/2019



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/9/2024
OSFM First Notify Date: 11/27/1989 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 8/8/2023 8/8/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2024 2/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/3/2024 2/3/2025
Overfill Prev Device Overfill Alarm 2/3/2024 2/3/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/28/2022 10/28/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/28/2022
Tank STIP3 Single Wall Precision Test (Tank) Pass 3/27/2019



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/9/2024
OSFM First Notify Date: 11/27/1989 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 10/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 8/8/2023 8/8/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2024 2/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/3/2024 2/3/2025
Overfill Prev Device Overfill Alarm 2/3/2024 2/3/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/28/2022 10/28/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/28/2022
Tank STIP3 Single Wall Precision Test (Tank) Pass 3/27/2019



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 4/17/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/18/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/13/2024 5/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/13/2024 5/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/13/2024 5/13/2025
Overfill Prev Device Overfill Alarm 5/13/2024 5/13/2027
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025
Spill Contain Device Double Wall Spill Bucket 4/29/2024 4/29/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 5/13/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 5/13/2024



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 4/17/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/18/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/13/2024 5/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/13/2024 5/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/13/2024 5/13/2025
Overfill Prev Device Overfill Alarm 5/13/2024 5/13/2027
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025
Spill Contain Device Double Wall Spill Bucket 4/29/2024 4/29/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 5/13/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 5/13/2024



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2024 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 4/17/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/18/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/13/2024 5/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/13/2024 5/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/13/2024 5/13/2025
Overfill Prev Device Overfill Alarm 5/13/2024 5/13/2027
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025
Spill Contain Device Double Wall Spill Bucket 4/29/2024 4/29/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 5/13/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 5/13/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/29/2024 4/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/13/2024 5/13/2025

MFD Motorfuel Dispensing Forms