Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1017538
Status: Closed
Facility Name: American Nickeloid Company
Address: 2900 W. Main Street Peru, IL 61354
County: LaSalle
Property Parcel: 17-18-483-000
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: T005078
Green Tag Issue Date: 11/28/2018
Green Tag Expire Date: 12/31/2020
MFD Type: N/A

Owner Details

Owner Name: American Nickeloid Company
Owner Address: 2900 W. Main Street Peru, IL 61354
Owner Status: Current Owner
Purchase Date: 10/2/1990
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/12/2021

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0000518 American Nickeloid Company Current Owner 10/2/1990

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: NAPTHA
Status: Removed CAS Code: 8030-30-6
Regulated Status: Federal Removed Date: 6/1/1988
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: -3 Abandoned Date:
Install Date: 2/7/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 500 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: MEK
Status: Removed CAS Code: 78-93-3
Regulated Status: Federal Removed Date: 6/1/1988
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 500 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: MEK
Status: Removed CAS Code: 78-93-3
Regulated Status: Federal Removed Date: 6/1/1988
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 25000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 4/1/1991
OSFM First Notify Date: 12/11/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 4/8/2021
OSFM First Notify Date: 4/22/1991 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/12/1991 Red Tag Issue Date:
Last Used Date: 12/31/1997 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 1/8/2020 1/8/2023
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik 950 1/7/2020 1/7/2021
Overfill Prev Device Overfill Drop Tube Valve 1/24/2019 1/24/2022
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 1/24/2019 1/24/2022
Tank STIP3 Double Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found