Facility Details
Facility Number:
1013864
Status:
Active
Facility Name:
Clean Fuel, Inc.
Address:
2233 Kishwaukee Rockford, IL 61104
County:
Winnebago
Property Parcel:
11-35-326-017
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA02099
Green Tag Issue Date:
8/13/2025
Green Tag Expire Date:
12/31/2027
MFD Type:
Self Service
Owner Details
Owner Name:
Kishwaukee Properties, LLC
Owner Address:
3 River HIlls Court Bolingbrook, IL 60490
Owner Status:
Current Owner
Purchase Date:
2/15/2013
Type of Financial Responsibility:
Designated Savings Account
Financial Responsibility Reporting Due Date:
9/8/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0036807
Kishwaukee Properties, LLC
Current Owner
2/15/2013
U0032946
JI Corp
Former Owner
3/23/2005
U0014088
Smith Oil Corporation
Former Owner
1/1/1988
U0003167
Coil Ernest
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
04-1756
Eligible
3/15/2005
3/31/2005
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 6
Capacity:
5500
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
6500
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
3000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
3000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
3000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 11
Capacity:
550
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 12
Capacity:
550
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 13
Capacity:
550
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/1/1989
OSFM
First Notify Date:
4/26/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 14
Capacity:
9728
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/1/1991
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
10/12/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/12/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/17/2025
11/17/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300c with CSLD
11/4/2025
11/4/2026
Overfill Prev Device
Ball Only Removed Ball Float Vent Valve
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
11/4/2025
11/4/2028
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
11/4/2025
11/4/2028
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping Ameron
Precision Test (Piping)
Pass
11/4/2025
Tank Number 15
Capacity:
9728
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/1/1991
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
10/12/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/12/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/21/2024
11/21/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300c with CSLD
11/4/2025
11/4/2026
Overfill Prev Device
Ball Only Removed Ball Float Vent Valve
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
11/4/2025
11/4/2028
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
11/4/2025
11/4/2028
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping Ameron
Precision Test (Piping)
Fail
11/4/2025
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found