Facility Number: 1013486
Status: Closed
Facility Name: Conserv FS
Address: 103 East 2nd Avenue Rochelle, IL 61068
County: Ogle
Property Parcel:
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: X003604
Green Tag Issue Date: 5/11/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Conserv FS, Inc.
Owner Address: 1110 McConnell Road Woodstock, IL 60098
Owner Status: Current Owner
Purchase Date: 6/1/2013
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 5/11/2022 12/31/2024
Self Service 1/30/2009 12/31/2010

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037234 Conserv FS, Inc. Current Owner 6/1/2013
U0036525 Stan Olsen Oils, Inc. Former Owner
U0012921 Rochelle Oil Company, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00532-2025REM Removal Approved / Issued 5/3/2025 5/5/2025 11/5/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0310 5/21/2025 Removal Log 00532-2025REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
06-1150 Eligible 1/29/2007 2/22/2007 $15,000
06-1150 Eligible 5/18/2012 7/17/2012 $15,000
20250310 Eligible 7/10/2025 7/11/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1050 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/29/1989
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: 11/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 550 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/29/1989
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 550 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/29/1989
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: 11/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/21/2025
OSFM First Notify Date: 2/7/1992 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date:
Last Used Date: 5/31/2024 Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 5/5/2022 5/5/2025
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 5/5/2022 5/5/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/21/2024 5/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 5/21/2024 5/21/2025
Overfill Prev Device Overfill Alarm 5/5/2022 5/5/2025
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/5/2022 5/5/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 5/21/2024



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/21/2025
OSFM First Notify Date: 2/7/1992 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date:
Last Used Date: 5/31/2024 Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 5/5/2022 5/5/2025
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 5/5/2022 5/5/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/21/2024 5/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 5/21/2024 5/21/2025
Overfill Prev Device Overfill Alarm 5/5/2022 5/5/2025
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/5/2022 5/5/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 5/21/2024



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/21/2025
OSFM First Notify Date: 2/7/1992 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date:
Last Used Date: 5/31/2024 Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 5/5/2022 5/5/2025
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 5/5/2022 5/5/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/21/2024 5/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 5/21/2024 5/21/2025
Overfill Prev Device Overfill Alarm 5/5/2022 5/5/2025
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/5/2022 5/5/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 5/21/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found