Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1010144
Status: Active
Facility Name: Becks
Address: 359 Third St
La Salle, IL 613012337
County: LaSalle
Property Parcel: 18-15-310-020
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002202
Green Tag Issue Date: 1/4/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Beck Oil Company of Illinois
Owner Address: 850 E. Thompson St.
Princeton, IL 61356
Owner Status: Current Owner
Purchase Date: 1/21/2009
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/4/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0001282 Beck Oil Company of Illinois Current Owner 1/21/2009
U0033021 Amtul, Inc. Former Owner 6/30/2005
U0031532 Baker Energy, Inc. Former Owner 8/27/2003
U0028787 Clark Retail Enterprises, Inc., Former Owner 7/12/1999
U0001851 Clark Former Owner 12/31/1967
U0029789 Clark Retail Enterprises, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0726 7/6/2011 Removal Log 00483-2011REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
05-1365 Eligible 2/7/2006 3/6/2006 $10,000
05-1365 Eligible 3/18/2009 4/9/2009 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/6/2011
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/8/1981 Red Tag Issue Date:
Last Used Date: 8/9/2007 Fee Due: $0.00
Product Date: 5/8/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/6/2011
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/1/1981 Red Tag Issue Date:
Last Used Date: 8/9/2007 Fee Due: $0.00
Product Date: 5/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Piping Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 10/16/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2024 6/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 6/13/2024 6/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 6/30/2022 6/30/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2022 6/30/2025
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 6/30/2022 6/30/2023
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025
Spill Contain Device Single Wall Spill Bucket 6/30/2022 6/30/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 6/13/2024



Tank Number 4

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 10/16/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2024 6/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 6/13/2024 6/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 6/30/2022 6/30/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2022 6/30/2025
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 6/30/2022 6/30/2023
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025
Spill Contain Device Single Wall Spill Bucket 6/30/2022 6/30/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 6/13/2024



Tank Number 5

Capacity: 7000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 10/16/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2024 6/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 6/13/2024 6/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 11/16/2022 11/16/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025
Spill Contain Device Single Wall Spill Bucket 11/15/2022 11/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 6/13/2024



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 10/16/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 6/13/2024 6/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 6/30/2022 6/30/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2022 6/30/2025
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 6/30/2022 6/30/2023
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025
Spill Contain Device Single Wall Spill Bucket 6/30/2022 6/30/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 7000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/2015 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 10/16/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/13/2024 6/13/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 6/13/2024 6/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 11/16/2022 11/16/2025
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025
Spill Contain Device Single Wall Spill Bucket 11/15/2022 11/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 6/13/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2022 6/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 6/13/2024 6/13/2025

MFD Motorfuel Dispensing Forms