Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1007419
Status: Active
Facility Name: Road Ranger #153
Address: 1101 North 7th Street Rochelle, IL 61068
County: Ogle
Property Parcel: 24-13-377-058
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001842
Green Tag Issue Date: 6/18/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Road Ranger, LLC
Owner Address: 1501 Woodfield Rd., Suite 300 S Schaumburg, IL 60173
Owner Status: Current Owner
Purchase Date: 2/1/2007
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0033990 Road Ranger, LLC Current Owner 2/1/2007
U0029627 Selex, LLC Former Owner
U0029552 North Star Trust Company Trust 00-2634 Former Owner
U0029552 North Star Trust Company Trust 00-2634 Former Owner
U0004910 Exel Sales Co., Inc. Former Owner / Operator

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260917 (Pending)    Issue Date: 4/7/2026    Expiration Date: 6/6/2026    View NOV Form

Tanks Violations
6, 7 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Handles are missing from both lids. Repair or replace. See 41 IAC Section 175.410.
Facility Missing copies of current testing certificates for operator training - Some C certifications are missing.
Facility Missing list of designated Class A/B & C Operators - List needs to be updated
7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Level is at the fill cap.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-1455 8/2/2000 Removal Log 01001-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-2653 Eligible 9/25/2000 10/11/2000 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/2/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: 11/16/1998 Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/2/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 11/16/1998 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/2/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 11/16/1998 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/2/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 11/16/1998 Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/2/2000
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 11/16/1998 Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/11/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 8/23/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/24/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/25/2026 3/25/2029
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/26/2026 2/26/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/26/2026 2/26/2027
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 6/20/2021 6/20/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/6/2024 6/6/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 4/28/2025



Tank Number 7

Capacity: 15000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/11/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 8/23/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/24/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/25/2026 3/25/2029
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/26/2026 2/26/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/26/2026 2/26/2027
Overfill Prev Device Overfill Drop Tube Valve 4/28/2025 4/28/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 6/20/2021 6/20/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/6/2024 6/6/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 4/28/2025
Tank Fiberglass Single Wall XERXES Precision Test (Tank) Pass 10/2/2019



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/2/2000
OSFM First Notify Date: 8/7/2000 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1979 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found