Facility Details
Facility Number:
1001798
Status:
Active
Facility Name:
Beck's #25
Address:
1301 13th Avenue
Mendota, IL 61342
County:
LaSalle
Property Parcel:
01-28-309-014
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Y002666
Green Tag Issue Date:
5/23/2023
Green Tag Expiration Date:
12/31/2025
Owner Details
Owner Name:
Beck Oil Company of Illinois
Owner Address:
850 E. Thompson St.
Princeton, IL 61356
Owner Status:
Current Owner
Purchase Date:
6/27/2013
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
6/28/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
3/22/2023
12/31/2025
Unattended Self Service
9/1/2015
12/31/2017
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0001282
Beck Oil Company of Illinois
Current Owner
6/27/2013
U0035551
Lakeview Food Shop, LLC
Former Owner
9/19/1996
U0006217
Gromann, Greg
Former Owner
6/1/1988
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
960881
5/21/1996
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
96-0881
Eligible
8/19/2014
8/21/2014
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1988
OSFM
First Notify Date:
2/10/1986
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1988
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1988
OSFM
First Notify Date:
2/10/1986
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1988
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1988
OSFM
First Notify Date:
2/10/1986
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1988
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
10/17/1988
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/14/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/28/2025
4/28/2026
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
4/28/2025
4/28/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/28/2025
4/28/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/28/2025
4/28/2028
Leak Detect - Piping
Sump Sensor
4/28/2025
4/28/2026
Spill Contain Device
Double Wall Spill Bucket
4/28/2025
4/28/2028
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
4/28/2025
Tank Number 5
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
10/17/1988
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/14/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/28/2025
4/28/2026
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
4/28/2025
4/28/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/28/2025
4/28/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/28/2025
4/28/2028
Leak Detect - Piping
Sump Sensor
4/28/2025
4/28/2026
Spill Contain Device
Single Wall Spill Bucket
4/28/2025
4/28/2028
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
4/28/2025
Tank Number 6
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
10/17/1988
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
8/14/1988
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/28/2025
4/28/2026
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
4/28/2025
4/28/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/28/2025
4/28/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/28/2025
4/28/2028
Leak Detect - Piping
Sump Sensor
4/28/2025
4/28/2026
Spill Contain Device
Single Wall Spill Bucket
4/28/2025
4/28/2028
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
4/28/2025
Tank Number 7
Capacity:
2000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/21/1996
OSFM
First Notify Date:
10/17/1988
Abandoned Material:
Current Age:
10
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
4/1/1996
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
550
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
5/1/1988
OSFM
First Notify Date:
11/15/1991
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1988
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
2000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
6/27/1996
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
5/16/1996
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/16/1996
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
4/28/2025
4/28/2026
Leak Detect - Tank
Automatic Tank Gauging Incon TS 550 with SCALD
4/28/2025
4/28/2026
Overfill Prev Device
Overfill Drop Tube Valve
4/28/2025
4/28/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/28/2025
4/28/2028
Leak Detect - Piping
Sump Sensor
4/28/2025
4/28/2026
Spill Contain Device
Double Wall Spill Bucket
4/28/2025
4/28/2028
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
4/28/2025
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 15/16
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 17/18
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
1001798
Beck's #25
Mendota
08/16/2017
Letter
Form