Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1001085
Status: Inactive
Facility Name: LCS 3, LLC
Address: 400 Old North Road Route 6 Spring Valley, IL 61362
County: Bureau
Property Parcel: 18-35-402-004
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: AA003633
Green Tag Issue Date: 5/9/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Fleet

Owner Details

Owner Name: LCS 3, LLC
Owner Address: P.O. Box 128 Spring Valley, IL 61362
Owner Status: Current Owner
Purchase Date: 9/23/2025
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 11/5/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041647 LCS 3, LLC Current Owner 9/23/2025
U0016258 Western Sand & Gravel Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020262418 (Pending)    Issue Date: 10/22/2026    Expiration Date: 12/21/2026    View NOV Form

Tanks Violations
6 Failed to Empty the Tank to 1" or Less - Out of service tanks are to be emptied to less than one inch. DSL tank contains 2272 gallons and the Gasoline tank has 105 (7 inches) Gallons per the ATG. This should be done before completing the notification forms.
6, 7 Submit Notification Form For Tank Status Change - Online notification forms can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1986 Abandoned Material:
Current Age: 32 Abandoned Date: 4/1/1991
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 22 Abandoned Date: 4/10/1991
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 22 Abandoned Date: 4/10/1991
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 22 Abandoned Date: 4/10/1991
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1986 Abandoned Material:
Current Age: 32 Abandoned Date: 4/1/1991
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 6

Capacity: 15000 Petroleum Use: Dispensing
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/11/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 3/1/1991 Red Tag Issue Date: 10/22/2026
Last Used Date: 10/22/2026 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/17/2025 10/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 10/17/2025 10/17/2026
Overfill Prev Device Ball Float Vent Valve 10/30/2024 10/30/2027
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Mechanical Other Non-vented check valve Functional Pass 4/15/2006
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/17/2025



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/11/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 4/1/1991 Red Tag Issue Date: 10/22/2026
Last Used Date: 10/22/2026 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/17/2025 10/17/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 10/17/2025 10/17/2026
Overfill Prev Device Ball Float Vent Valve 10/30/2024 10/30/2027
Piping Flex Connector Steel Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Mechanical Other Non-vented check valve Functional Pass 4/15/2006
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/17/2025

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID Unleaded

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found