Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1000039
Status: Active
Facility Name: Casey's #1305
Address: 70 South Somonauk Road Cortland, IL 60112
County: De Kalb
Property Parcel: 09-29-205-019
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001904
Green Tag Issue Date: 8/30/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 7/28/1986
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 7/28/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261245 (Pending)    Issue Date: 5/12/2026    Expiration Date: 7/11/2026    View NOV Form

Tanks Violations
1, 2 Miscellaneous - ATG in multiple alarms
Facility Missing copies of current testing certificates for operator training
Facility Missing list of designated Class A/B & C Operators - LEFT BLANK ONSITE.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/16/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/24/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/24/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/9/2026 1/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/9/2026 1/9/2027
Overfill Prev Device Ball Float Vent Valve OPW 53V 3/25/2026 3/25/2029
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/9/2026 1/9/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/16/1987 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/24/1986 Red Tag Issue Date: 5/12/2026
Last Used Date: Fee Due: $0.00
Product Date: 9/24/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/9/2026 1/9/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/9/2026 1/9/2027
Overfill Prev Device Ball Float Vent Valve OPW 53V 3/25/2026 3/25/2029
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/9/2026 1/9/2029
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Fail 4/27/2026

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found