Division of Petroleum & Chemical Safety

 

Facility: 7042092 Tank: 7

Click for Facility/Tank Ownership history

Capacity: 20000
Product: B-99
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 9/10/2012
Current Age: 11
Install Date: 7/26/2012
Last Used Date:
Product Date: 7/26/2012
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/27/2023 9/27/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/27/2023 9/27/2024
Overfill Prev Device Overfill Alarm 10/26/2022 10/26/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump Tank Top 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor with positive shutdown 6/29/2022 9/27/2023 9/27/2024
Piping Single Wall Transition Sump Soy Meter South 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/27/2023 9/27/2024
Piping Single Wall Transition Sump Soy Meter West 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/27/2023 9/27/2024
Piping Single Wall Transition Sump Soy Meter East 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/27/2023 9/27/2024
Spill Contain Device Single Wall Spill Bucket Remote Fill 12/10/2021 12/10/2024
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary06062022-091806.pdf Approved 6/6/2022

Compatibility Form Attachments

File Name Description
577014-449-01_Aluminum_Mag_Plus_In-Tank_Probe.pdf ATG Probe
577014-449-01_Aluminum_Mag_Plus_In-Tank_Probe.pdf ATG Probe
Vedder Root-PLLD compat state.pdf Electronic Pressurized Line Leak Detection
Vedder Root-PLLD compat state.pdf Electronic Pressurized Line Leak Detection
Dualoy+3000+LCX+Data+Sheet.pdf Fiberglass Double Wall
Dualoy+3000+LCX+Data+Sheet.pdf Fiberglass Double Wall
biofuel-compatibility+CSI+tanks.pdf Fiberglass Double Wall
biofuel-compatibility+CSI+tanks.pdf Fiberglass Double Wall
!!!!Veeder-Root - Fuel Compatibility Letter - Executed - 2015-09-23 (2).pdf Non-Discriminating Interstitial Monitoring Sensors
577013-750-17_NonDescrinatingMicroSensor_1 B99 & E85.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
!!!!Veeder-Root - Fuel Compatibility Letter - Executed - 2015-09-23 (2).pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
576047-241_Overfill_Alarm.pdf Overfill Alarm
576047-241_Overfill_Alarm.pdf Overfill Alarm
OPW+1-2105+compatibility+sheet (2).pdf Single Wall Spill Bucket
OPW+1-2105+compatibility+sheet (2).pdf Single Wall Spill Bucket
bravo_afton (1).pdf Single Wall STP/Tanktop Sump
bravo_afton (1).pdf Single Wall STP/Tanktop Sump
Red Jacket Pumps.pdf STP
!!!!Veeder-Root - Fuel Compatibility Letter - Executed - 2015-09-23 (2).pdf STP
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf Transition Sumps
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf Transition Sumps
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf UDC
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf UDC

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Precision Test Pass 9/27/2023 Show History