Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7044953
Status: Active
Facility Name: Kroger #L-672
Address: 95 Plaza Dr
Anna, IL 62906
County: Union
Property Parcel: 0000000000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Y000954
Green Tag Issue Date: 8/8/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Kroger Limited Partnership I
Owner Address: 1600 Ormsby Station Court
Louisville, KY 40223
Owner Status: Current Owner
Purchase Date: 1/1/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/8/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030137 Kroger Limited Partnership I Current Owner 1/1/2014

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/15/2011 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 11/9/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/19/2024 3/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/19/2024 3/19/2025
Overfill Prev Device Overfill Alarm 4/20/2022 4/20/2025
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025
Spill Contain Device Single Wall Spill Bucket 4/20/2022 4/20/2025
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test Pass 3/19/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 4/13/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/15/2011 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 11/9/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/19/2024 3/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/19/2024 3/19/2025
Overfill Prev Device Overfill Alarm 4/20/2022 4/20/2025
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025
Spill Contain Device Single Wall Spill Bucket 4/20/2022 4/20/2025
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test Pass 3/19/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 4/13/2023



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/15/2011 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 11/9/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/19/2024 3/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/19/2024 3/19/2025
Overfill Prev Device Overfill Alarm 4/20/2022 4/20/2025
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025
Spill Contain Device Single Wall Spill Bucket 4/20/2022 4/20/2025
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test Pass 3/19/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 4/13/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/20/2022 4/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/19/2024 3/19/2025

MFD Motorfuel Dispensing Forms

No Forms Found