Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7041693
Status: Active
Facility Name: Acees
Address: 612 East Vine Street
Vienna, IL 62995
County: Johnson
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001144
Green Tag Issue Date: 1/31/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Acees, Inc.
Owner Address: 5820 Cairo Road
Paducah, KY 42001
Owner Status: Current Owner
Purchase Date: 7/1/2012
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 1/18/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/31/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038334 Acees, Inc. Current Owner 7/1/2012
U0036576 Cheers Food & Fuel, Inc. Former Owner 6/11/2012
U0031302 Cagle, Bill and Sue Former Owner 9/10/2003

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/13/2003 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 9/10/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/10/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/6/2023 7/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 7/6/2023 7/6/2024
Overfill Prev Device Overfill Drop Tube Valve 9/29/2021 9/29/2024
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024
Spill Contain Device Double Wall Spill Bucket 8/12/2021 8/12/2024
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test Pass 5/21/2020



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/13/2003 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 9/10/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/10/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/6/2023 7/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 7/6/2023 7/6/2024
Overfill Prev Device Overfill Drop Tube Valve 9/29/2021 9/29/2024
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024
Spill Contain Device Double Wall Spill Bucket 8/12/2021 8/12/2024
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test Pass 5/21/2020



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/13/2003 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 9/10/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/10/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/6/2023 7/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 7/6/2023 7/6/2024
Overfill Prev Device Overfill Drop Tube Valve 9/29/2021 9/29/2024
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024
Spill Contain Device Double Wall Spill Bucket 8/12/2021 8/12/2024
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech XP 1500 Precision Test Pass 5/21/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2022 8/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2022 8/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2022 8/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2022 8/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/6/2023 7/6/2024