Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7039136
Status: Active
Facility Name: Acees
Address: 510 Front Street
Dongola, IL 62926
County: Union
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003433
Green Tag Issue Date: 7/11/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Acees, Inc.
Owner Address: 5820 Cairo Road
Paducah, KY 42001
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 1/18/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/11/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038334 Acees, Inc. Current Owner
U0030760 Golightly & Long, LLC Former Owner 5/1/2002
U0022089 Duke & Long Distributing Co., Inc. Former Owner 12/1/1994

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
19-1046 11/21/2019 Abandonment Log 02077-2019ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20191046 Eligible 11/5/2019 11/5/2019 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/2/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 43 Abandoned Date: 11/21/2019
Install Date: 5/2/1981 Red Tag Issue Date:
Last Used Date: 9/21/2018 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 5/1/2018 5/1/2019
Corrosion Prot - Tank Impressed Current Cathodic Protection 5/1/2018 5/1/2019
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 7/1/2019
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 6/8/2015



Tank Number 2

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 5/2/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/22/2023 6/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/22/2023 6/22/2024
Overfill Prev Device Overfill Drop Tube Valve 6/11/2021 6/11/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/28/2022 7/28/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/11/2021
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 6/8/2015



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 5/2/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/22/2023 6/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/22/2023 6/22/2024
Overfill Prev Device Overfill Drop Tube Valve 6/11/2021 6/11/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/28/2022 7/28/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/11/2021
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 6/8/2015



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/28/1997 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 5/2/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/22/2023 6/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/22/2023 6/22/2024
Overfill Prev Device Overfill Drop Tube Valve 6/11/2021 6/11/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/28/2022 7/28/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/18/2021
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 6/8/2015



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/28/1997 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 5/2/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/28/2023 8/28/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/22/2023 6/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/22/2023 6/22/2024
Overfill Prev Device Overfill Drop Tube Valve 9/5/2023 9/5/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/28/2022 7/28/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/18/2021
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 6/8/2015

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found