Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7025427
Status: Closed
Facility Name: McLeansboro High School
Address: 200 S. Pearl Street
McLeansboro, IL 62859
County: Hamilton
Property Parcel:
Facility Type: School/College
Owner Type: Other Local
Green Tag Decal: N005699
Green Tag Issue Date: 10/4/2012
Green Tag Expiration Date: 12/31/2014

Owner Details

Owner Name: Hamilton County School District
Owner Address: 109 N. Washington
P.O. Box 369
McLeansboro, IL 62859
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/9/2013

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/4/2012 12/31/2014

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0006377 Hamilton County School District Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
13-0570 6/5/2013 Removal Log 00463-2013REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
13-0570 Eligible 7/22/2013 8/23/2013 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/1990
OSFM First Notify Date: 2/15/1989 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: 6/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 560 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/1990
OSFM First Notify Date: 2/15/1989 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: 6/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/5/2013
OSFM First Notify Date: 10/20/1992 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 8/20/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/22/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/30/2012 4/30/2015
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/30/2012 4/30/2015
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank SIR and Prec Tightness Testing USTman Industries
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing USTman Industries Precision Test (Tank) Pass 4/24/2012



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/5/2013
OSFM First Notify Date: 10/20/1992 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 8/20/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/22/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/30/2012 4/30/2015
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/30/2012 4/30/2015
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank SIR and Prec Tightness Testing USTman Industries
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing USTman Industries Precision Test (Tank) Pass 4/24/2012

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found