Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7023255
Status: Active
Facility Name: Ekansh, Inc.
Address: 200 N. Front Street
Cobden, IL 62920
County: Union
Property Parcel: 14-00-09-916
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: W005197
Green Tag Issue Date: 11/15/2021
Green Tag Expiration Date: 12/31/2023

Owner Details

Owner Name: Ekansh, Inc.
Owner Address: 200 N. Front Street
Cobden, IL 62920
Owner Status: Current Owner
Purchase Date: 4/10/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/9/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/15/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039638 Ekansh, Inc. Current Owner 4/10/2019
U0038852 Lucamia, Inc. Former Owner 7/28/2017
U0034044 Alchemist USA, LLC Former Owner 2/21/2007
U0015667 Veach Oil Company Former Owner 1/1/1961

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020231032 (Referred to Legal)    Issue Date: 4/25/2023    Expiration Date: 6/24/2023    View NOV Form

Tanks Deficiency
2, 4 Annual leak detection certification not completed (Required annually). - Verified with Tank Tech and the payment has been made, a permit will be acquired 7-12-23 along with a NOV extension request.
Facility Missing copies of Annual Walkthrough Inspection Report. - Verified with Tank Tech and the payment has been made, a permit will be acquired 7-12-23 along with a NOV extension request.
2, 4 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Verified with Tank Tech and the payment has been made, a permit will be acquired 7-12-23 along with a NOV extension request.
2, 4 Precision tank test required. - Due to not having any tank test records on site.
2 Tank internal lining inspection past due (Required every 5 years). - Verified with Tank Tech and the payment has been made, a permit will be acquired 7-12-23 along with a NOV extension request.
2, 4 Triennial spill prevention equipment testing not completed. - Verified with Tank Tech and the payment has been made, a permit will be acquired 7-12-23 along with a NOV extension request.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
18-0112 3/7/2018 Abandonment Log 00178-2018ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20180112 Eligible 3/23/2018 3/27/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 56 Abandoned Date: 3/7/2018
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 10/30/2012 10/30/2017
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/1986 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date: 11/29/2023
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal Bridgeport Chemical Glass Armor GA 27P 12/21/2017 12/21/2022
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 12/18/2023 12/18/2024
Overfill Prev Device Overfill Drop Tube Valve 12/18/2023 12/18/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/18/2023 12/18/2026
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 12/18/2023



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/29/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 56 Abandoned Date: 3/7/2018
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 6/26/2007 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1996 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 10/16/1996 Red Tag Issue Date: 11/29/2023
Last Used Date: Fee Due: $0.00
Product Date: 10/16/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 12/18/2023 12/18/2024
Overfill Prev Device Overfill Drop Tube Valve 12/18/2023 12/18/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/18/2023 12/18/2026
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Composite Single Wall ACT 100 Precision Test (Tank) Pass 12/18/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found