Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7021608
Status: Active
Facility Name: KKG2, Inc. d/b/a Cisne Citgo
Address: 600 Rt. 45 South
Cisne, IL 62823
County: Wayne
Property Parcel: 03-50-042-014
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000056
Green Tag Issue Date: 4/24/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: ARG KK10PCK001, LLC
Owner Address: 38 Washington Square
Newport, RI 02840
Owner Status: Current Owner
Purchase Date: 12/11/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/1/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/18/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040111 ARG KK10PCK001, LLC Current Owner 12/11/2020
U0008547 Knapp Oil Company, Inc. Former Owner
U0009042 Legg & Sons Oil Co Inc Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00289-2024LIN Lining Inspection Approved / Issued 3/14/2024 3/14/2024 9/16/2024 Documents

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-0171 4/1/2014 Abandonment Log 00191-2014ABN
19-0442 5/29/2019 Removal Log 00876-2019REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0171 Eligible 5/27/2014 7/1/2014 $5,000
20190442 Eligible 6/26/2019 7/2/2019 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 5/6/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal Bridgeport Chemical Glass Armor GA 27P 4/4/2024 4/4/2029
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/28/2023 11/28/2024
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 11/28/2023 11/28/2024
Overfill Prev Device Overfill Drop Tube Valve 12/9/2021 12/9/2024
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor 11/28/2023 11/28/2024
Spill Contain Device Single Wall Spill Bucket 12/9/2021 12/9/2024
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 12/9/2022
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 11/28/2023
Tank Steel Single Wall Precision Test (Tank) Pass 4/6/2024



Tank Number 2

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/29/2019
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 5/6/1983 Red Tag Issue Date:
Last Used Date: 1/22/2019 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 10/24/2013 10/24/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/1/2018 8/1/2019
Leak Detect - Piping Sump Sensor 10/31/2018 10/31/2019
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 12/26/2018 12/26/2019
Overfill Prev Device Overfill Drop Tube Valve 12/26/2018 12/26/2021
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 12/26/2018 12/26/2021
Spill Contain Device Single Wall Spill Bucket 12/26/2018 12/26/2021
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use: None
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/29/2019
OSFM First Notify Date: 5/6/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 21 Abandoned Date: 4/1/2014
Install Date: Red Tag Issue Date:
Last Used Date: 10/24/2013 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/30/2008 9/30/2013
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/29/2019
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 16 Abandoned Date: 2/1/2001
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/19/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/19/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Jacketed Steel Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/28/2023 11/28/2024
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 11/28/2023 11/28/2024
Overfill Prev Device Overfill Drop Tube Valve 12/8/2022 12/8/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor 11/28/2023 11/28/2024
Spill Contain Device Single Wall Spill Bucket 12/8/2022 12/8/2025
Tank Jacketed Steel Single Wall Total Containment N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 12/9/2022
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 11/28/2023
Tank Jacketed Steel Single Wall Total Containment Precision Test (Tank) Pass 12/5/2022



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 5/3/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 5/3/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 5/3/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 5/3/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 4000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 5/3/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 2/25/1991 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1901 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 12/10/1991 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1901 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 13

Capacity: 560 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 2/1/1991
OSFM First Notify Date: 12/16/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/11/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 14

Capacity: 6000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/31/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 6/5/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/5/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/28/2023 11/28/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/28/2023 11/28/2024
Overfill Prev Device Overfill Drop Tube Valve 12/9/2021 12/9/2024
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor with positive shutdown 11/28/2023 11/28/2024
Spill Contain Device Double Wall Spill Bucket 12/9/2021 12/9/2024
Tank Composite Double Wall Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 11/28/2023
Piping Flexible Double Wall A.P.T. Poly Tech S150SC Precision Test Pass 8/6/2019
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 12/5/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor 11/28/2023 11/28/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor 11/28/2023 11/28/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor 11/28/2023 11/28/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/9/2021 12/9/2024
Leak Detect - Piping Sump Sensor with positive shutdown 11/28/2023 11/28/2024

MFD Motorfuel Dispensing Forms