Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7016008
Status: Active
Facility Name: Jones Service Station
Address: 27239 State Hwy 3
Olive Branch, IL 62969
County: Alexander
Property Parcel: 06-32-151-013
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002447
Green Tag Issue Date: 5/19/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Robert Jones
Owner Address: Box 398, Highway 3
Olive Branch, IL 62969
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/13/2023

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Full Service 5/19/2022 12/31/2024
Self Service 5/19/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008098 Jones, Robert Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00426-2024LIN Lining Inspection Approved / Issued 4/17/2024 4/17/2024 10/17/2024 Documents

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
08-0080 5/28/2008 Removal Log 00812-2008REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-0080 Eligible 8/14/2008 8/27/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/7/1986 Abandoned Material:
Current Age: 58 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal Bridgeport Chemical Glass Armor GA 27P 7/26/2019 7/26/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/9/2023 3/9/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 3/9/2023 3/9/2024
Overfill Prev Device Overfill Drop Tube Valve 3/8/2021 3/8/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/4/2021 3/4/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 3/9/2023
Tank Steel Single Wall Precision Test (Tank) Pass 7/29/2019



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/28/2008
OSFM First Notify Date: 4/7/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 8/17/2007 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Lining Materials Internal

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/7/1986 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 11/4/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Stand Alone System Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/9/2023 3/9/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 3/9/2023 3/9/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/9/2023 3/9/2024
Overfill Prev Device Overfill Drop Tube Valve 3/9/2022 3/9/2025
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/9/2022 3/9/2025
Tank Stand Alone System N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test Pass 3/9/2023
Tank Stand Alone System Precision Test (Tank) Pass 12/2/2019
Tank Steel Single Wall Precision Test (Tank) Pass 9/23/2019



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/14/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 7/16/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/17/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/9/2023 3/9/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 3/9/2023 3/9/2024
Overfill Prev Device Overfill Drop Tube Valve 3/4/2021 3/4/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/4/2021 3/4/2024
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 3/9/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found