Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7015583
Status: Closed
Facility Name: Southern Custom Foam, Inc.
Address: 50 Greenhill Rd.
Eldorado, IL 62930
County: Saline
Property Parcel:
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: D001861
Green Tag Issue Date: 2/27/2002
Green Tag Expiration Date: 12/31/2005

Owner Details

Owner Name: Southern Custom Foam, Inc.
Owner Address: 101 E. DeYoung Street
Marion, IL 62959
Owner Status: Current Owner
Purchase Date: 12/15/2004
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 2/4/2009

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032634 Southern Custom Foam, Inc. Current Owner 12/15/2004
U0013666 Scot Lad Foods Inc Former Owner 1/1/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
09-1051 11/3/2009 Removal Log 01235-2009REM
09-1051 11/4/2009 Removal Log 01235-2009REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-1661 Eligible 11/4/1998 12/30/1998 $10,000
09-1051 Eligible 12/15/2009 2/1/2010 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/3/2009
OSFM First Notify Date: 2/8/1993 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 9/1/1991 Red Tag Issue Date:
Last Used Date: 12/15/2004 Fee Due: $0.00
Product Date: 9/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/4/2009
OSFM First Notify Date: 2/8/1993 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 9/1/1991 Red Tag Issue Date:
Last Used Date: 12/15/2004 Fee Due: $0.00
Product Date: 9/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 57 Abandoned Date: 9/6/1990
Install Date: 1/1/1967 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1967

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 55 Abandoned Date: 10/7/1998
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 12/1/1997 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 2000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/7/1998
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 3/1/1998 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 2000 Petroleum Use:
Product: New Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 29 Abandoned Date: 10/7/1998
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1978 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found