Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7011932
Status: Active
Facility Name: Marion Unit #2 Bus Garage
Address: 200 North 5th Street
Marion, IL 62959
County: Williamson
Property Parcel:
Facility Type: School/College
Owner Type: Other Local
Green Tag Decal: Z003655
Green Tag Issue Date: 1/11/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Marion CUSD #2
Owner Address: 1700 West Cherry Street
Marion, IL 62959
Owner Status: Current Owner
Purchase Date: 9/9/1991
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 9/21/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/11/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013590 Marion CUSD #2 Current Owner 9/9/1991

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
91-2400 8/26/1991 Removal Log
N/A 10/30/2020 Abandonment Log 01466-2020ABN

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1991
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1991
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1991
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1992 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/18/2023 4/18/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/18/2023 4/18/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 4/18/2023 4/18/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket Insert 4/18/2023 4/18/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1992 Abandoned Material: Piping Capped Off
Current Age: 32 Abandoned Date: 10/30/2020
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/15/2018 2/15/2021
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 2/15/2018 2/15/2021
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Manhole Field Constructed 7/6/2020 7/6/2023
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID Gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found