Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7007501
Status: Active
Facility Name: Hucks #51
Address: 101 S. 45th Street
Mount Vernon, IL 62867
County: Jefferson
Property Parcel: 06-35-100-007
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000087
Green Tag Issue Date: 8/2/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Martin & Bayley, Inc.
Owner Address: P.O. Box 385
Carmi, IL 62821
Owner Status: Current Owner
Purchase Date: 1/1/1984
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 9/24/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/2/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009763 Martin & Bayley, Inc. Current Owner 1/1/1984
U0001538 Big Wheelers Truckstop Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
22-0564 7/27/2022 Removal Log 00692-2022REM
22-0564 8/17/2022 Removal Log 00692-2022REM
22-0564 8/18/2022 Removal Log 00692-2022REM
N/A 7/19/2022 Abandonment Log 00705-2022ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-1631 Eligible 2/10/2005 3/7/2005 $10,000
20220564 Eligible 11/9/2022 11/15/2022 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/18/2022
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 3/10/2022 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/11/2021 10/11/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/11/2021 10/11/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2021 10/11/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/11/2021 10/11/2022
Overfill Prev Device Overfill Drop Tube Valve 1/25/2019 1/25/2022
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/25/2019 1/25/2022
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/11/2021



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/18/2022
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 3/10/2022 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/11/2021 10/11/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/11/2021 10/11/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2021 10/11/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/11/2021 10/11/2022
Overfill Prev Device Overfill Drop Tube Valve 10/11/2021 10/11/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/1/2021 12/1/2024
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/11/2021
Tank Steel Single Wall Precision Test (Tank) Pass 9/10/2020



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2022
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 3/10/2022 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/11/2021 10/11/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/11/2021 10/11/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2021 10/11/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 10/11/2021 10/11/2022
Overfill Prev Device Overfill Drop Tube Valve 10/11/2021 10/11/2024
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/1/2021 12/1/2024
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/11/2021



Tank Number 4

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/27/2022
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 6/16/2022 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/11/2021 10/11/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/11/2021 10/11/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2021 10/11/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/1/2021 12/1/2022
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
Overfill Prev Device Overfill Drop Tube Valve 11/8/2021 11/8/2024
Piping Blending Sump 9/24/2021 9/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/1/2021 12/1/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/23/2020 12/23/2023
Leak Detect - Piping Non-Discriminating Sump Sensor 7/30/2020 7/30/2021
Leak Detect - Piping Sump Sensor with positive shutdown 12/1/2021 12/1/2022
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/25/2019 1/25/2022
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test Pass 10/11/2021
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/11/2021
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 12/15/2021
Tank Steel Single Wall Precision Test (Tank) Pass 12/15/2021



Tank Number 5

Capacity: 20000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/27/2022
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 6/16/2022 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/11/2021 10/11/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/11/2021 10/11/2022
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/1/2021 12/1/2022
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
Overfill Prev Device Overfill Drop Tube Valve 11/8/2021 11/8/2024
Piping Blending Sump 9/24/2021 9/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/1/2021 12/1/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor
Leak Detect - Piping Non-Discriminating Sump Sensor 7/30/2019 7/30/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/25/2019 1/25/2022
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test Pass 10/11/2021
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/11/2021
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 12/15/2021
Tank Steel Single Wall Precision Test (Tank) Pass 12/15/2021



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/22/1986 Abandoned Material: Gravel
Current Age: 39 Abandoned Date: 7/19/2022
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 6/16/2022 Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/11/2021 10/11/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/11/2021 10/11/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2021 10/11/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/1/2021 12/1/2022
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
Overfill Prev Device Overfill Drop Tube Valve 11/8/2021 11/8/2024
Piping Blending Sump 9/24/2021 9/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/1/2021 12/1/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 7/30/2019 7/30/2020
Leak Detect - Piping Non-Discriminating Sump Sensor 7/30/2020 7/30/2021
Leak Detect - Piping Sump Sensor with positive shutdown 12/1/2021 12/1/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/8/2021 11/8/2024
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test Pass 10/11/2021
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/11/2021
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D Precision Test (Tank) Pass 12/15/2021
Tank Steel Single Wall Precision Test (Tank) Pass 12/15/2021



Tank Number 7

Capacity: 20000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 6/8/2022
Piping Steel Single Wall Piping Precision Test Pass 6/8/2022
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022



Tank Number 8

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: 6/29/2022 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 1/21/2022
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 6/8/2022
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022



Tank Number 9

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: 6/29/2022 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 1/21/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 6/8/2022
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022



Tank Number 10

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/13/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022



Tank Number 11

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/13/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022



Tank Number 12

Capacity: 10000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/13/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022



Tank Number 13

Capacity: 7000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/16/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/30/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/13/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/12/2024 3/12/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Double Wall Spill Bucket 3/12/2024 3/12/2027
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/12/2024
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 1/21/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 17M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 18S/18M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 19S/19M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 20S/20M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 21S/21M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 22S/22M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 23S/23M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 24S/24M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 25S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/12/2024 3/12/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
7007501 Hucks #51 Mount Vernon 05/31/2022 Letter Form
7007501 Hucks #51 Mount Vernon 02/14/2022 Letter Form