Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6026396
Status: Active
Facility Name: Southwestern Illinois Bus Co., LLC
Address: 2421 Old Plank Rd
Chester, IL 62233
County: Randolph
Property Parcel:
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Y003450
Green Tag Issue Date: 1/13/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Southwestern Illinois Bus Co., LLC
Owner Address: 2421 Old Plank Road
Chester, IL 62233
Owner Status: Current Owner / Operator
Purchase Date: 6/27/2007
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 7/17/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/13/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034504 Southwestern Illinois Bus Co., LLC Current Owner / Operator 6/27/2007
U0004605 Eggemeyer Jerry L Former Owner / Operator 6/27/2007

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/7/1990 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 1/4/2021 1/4/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/17/2023 7/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/9/2022 8/9/2025
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/9/2022 8/9/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/7/1990 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 1/4/2021 1/4/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/17/2023 7/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/9/2022 8/9/2025
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/9/2022 8/9/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID DIESEL

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID RUL

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms