Facility Number: 6024946
Status: Active
Facility Name: UPS Distribution Center
Address: 1149 East Airline Drive
East Alton, IL 62024
County: Madison
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y004532
Green Tag Issue Date: 4/17/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: BT-OH, LLC (Formerly Brookind Corporation)
Owner Address: 55 Glenlake Parkway, NE
Atlanta, GA 30346
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/26/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 4/17/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002003 BT-OH, LLC (Formerly Brookind Corporation) Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1989 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 12/5/1988 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/19/2023 9/19/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/19/2023 9/19/2024
Overfill Prev Device Overfill Drop Tube Valve 9/8/2021 9/8/2024
Piping Fiberglass Chase N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 9/8/2021 9/8/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2023 9/19/2024
Spill Contain Device Single Wall Spill Bucket 9/8/2021 9/8/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 9/19/2023
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 8/7/2020



Tank Number 2

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/6/1993
OSFM First Notify Date: 5/1/1989 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms