Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6024654
Status: Closed
Facility Name: former Thomeczek Oil Co.
Address: 1750 Fosterburg Road, Box 66
Alton, IL 62002
County: Madison
Property Parcel:
Facility Type: Bulk Plant
Owner Type: Other Local
Green Tag Decal: D001601
Green Tag Issue Date: 1/10/2002
Green Tag Expiration Date: 12/31/2005

Owner Details

Owner Name: Vex Properties, Inc.
Owner Address: 1801 N. Belt West, Suite #4
Belleville, IL 62226
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 7/8/2009

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034822 Vex Properties, Inc. Current Owner
U0014970 Thomeczek Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
08-1281 10/14/2008 Removal Log 01579-2008REM
08-1281 10/14/2008 Removal Log 01579-2008REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-1281 Eligible 12/11/2008 1/5/2009 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2008
OSFM First Notify Date: 2/10/1989 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 2/1/1989 Red Tag Issue Date:
Last Used Date: 10/17/2005 Fee Due: $0.00
Product Date: 2/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Tank Automatic Tank Gauging
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2008
OSFM First Notify Date: 2/10/1989 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 2/1/1989 Red Tag Issue Date:
Last Used Date: 10/17/2005 Fee Due: $0.00
Product Date: 2/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Tank Automatic Tank Gauging
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2008
OSFM First Notify Date: 2/10/1989 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 2/1/1989 Red Tag Issue Date:
Last Used Date: 10/17/2005 Fee Due: $0.00
Product Date: 2/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Tank Automatic Tank Gauging
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2008
OSFM First Notify Date: 2/10/1989 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 2/1/1989 Red Tag Issue Date:
Last Used Date: 10/17/2005 Fee Due: $0.00
Product Date: 2/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Tank Automatic Tank Gauging
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2008
OSFM First Notify Date: 2/10/1989 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 2/1/1989 Red Tag Issue Date:
Last Used Date: 10/17/2005 Fee Due: $0.00
Product Date: 2/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Tank Automatic Tank Gauging
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2008
OSFM First Notify Date: 2/17/1989 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/17/2005 Fee Due: $0.00
Product Date: 2/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Tank Automatic Tank Gauging
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms