Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6020837
Status: Active
Facility Name: Ameren Illinois Belleville Operating Center
Address: 1050 West Boulevard
Belleville, IL 62220
County: St. Clair
Property Parcel:
Facility Type: Utility
Owner Type: Private
Green Tag Decal: X003662
Green Tag Issue Date: 10/13/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Ameren Illinois
Owner Address: 300 Liberty Street
Peoria, IL 61602
Owner Status: Current Owner
Purchase Date: 10/1/2010
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/13/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038114 Ameren Illinois Current Owner 10/1/2010
U0029796 Ameren CIPS Former Owner 10/1/2010
U0007405 Illinois Power Company d/b/a Ameren IP Former Owner 12/16/1957

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
93-0301 8/31/1993 Removal Log
94-0283 10/21/1994 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-0301 Eligible 9/20/1993 11/19/1993 $10,000
94-0283 Eligible 3/16/1994 3/30/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/21/1994
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1966

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/21/1994
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/31/1993
OSFM First Notify Date: 12/6/1994 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: 2/2/1993 Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1994 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/14/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/14/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/27/2024 3/27/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 3/27/2024 3/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/27/2024 3/27/2025
Overfill Prev Device Overfill Drop Tube Valve 3/7/2022 3/7/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/7/2022 3/7/2025
Leak Detect - Piping Sump Sensor 3/27/2024 3/27/2025
Spill Contain Device Single Wall Spill Bucket 3/7/2022 3/7/2025
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 3/27/2024



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1994 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/14/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/14/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/27/2024 3/27/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 3/27/2024 3/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/27/2024 3/27/2025
Overfill Prev Device Overfill Drop Tube Valve 3/7/2022 3/7/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/7/2022 3/7/2025
Leak Detect - Piping Sump Sensor 3/27/2024 3/27/2025
Spill Contain Device Single Wall Spill Bucket 3/7/2022 3/7/2025
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 3/27/2024

Dispenser Information



Name\ID 1/2/3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found