Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6019211
Status: Active
Facility Name: CC Food Mart
Address: 550 S. Madison
Lebanon, IL 62254
County: St. Clair
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000173
Green Tag Issue Date: 5/17/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Clinton County Oil Company, Inc.
Owner Address: P.O. Box 155
Breese, IL 62230
Owner Status: Current Owner
Purchase Date: 12/1/1984
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 1/23/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/17/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0003121 Clinton County Oil Company, Inc. Current Owner 12/1/1984

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-1693 Eligible 10/24/2005 11/28/2005 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 51 Abandoned Date: 3/9/2005
Install Date: 8/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 51 Abandoned Date: 3/9/2005
Install Date: 8/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 51 Abandoned Date: 3/9/2005
Install Date: 8/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 46 Abandoned Date: 3/9/2005
Install Date: 9/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 39 Abandoned Date: 10/3/2013
Install Date: 4/1/1985 Red Tag Issue Date:
Last Used Date: 6/1/2013 Fee Due: $0.00
Product Date: 4/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/24/2011 2/24/2012
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/24/2011 2/24/2012
Leak Detect - Piping Sump Sensor 2/24/2011 2/24/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 13000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/4/2005 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 12/9/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/9/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/6/2024 3/6/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/6/2024 3/6/2025
Overfill Prev Device Ball Float Vent Valve 1/18/2022 1/18/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/18/2022 1/18/2025
Leak Detect - Piping Sump Sensor 3/6/2024 3/6/2025
Spill Contain Device Single Wall Spill Bucket 1/18/2022 1/18/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/4/2005 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 12/9/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/9/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/6/2024 3/6/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/6/2024 3/6/2025
Overfill Prev Device Overfill Drop Tube Valve 1/18/2022 1/18/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/18/2022 1/18/2025
Leak Detect - Piping Sump Sensor 3/6/2024 3/6/2025
Spill Contain Device Single Wall Spill Bucket 1/18/2022 1/18/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 5/29/2019



Tank Number 8

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/6/2013 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/14/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/14/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/6/2024 3/6/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/6/2024 3/6/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/6/2024 3/6/2025
Overfill Prev Device Overfill Drop Tube Valve 1/18/2022 1/18/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/18/2022 1/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2024 3/6/2025
Spill Contain Device Single Wall Spill Bucket 1/18/2022 1/18/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 10S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/18/2022 1/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/6/2024 3/6/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms