Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6009979
Status: Closed
Facility Name: Raqqa Food Mart
Address: 1316 Vandalia Street
Collinsville, IL 62234
County: Madison
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: L002249
Green Tag Issue Date: 11/30/2010
Green Tag Expiration Date: 12/31/2012

Owner Details

Owner Name: IDOT District #8
Owner Address: 1102 East Port Plaza Drive
Collinsville, IL 62234
Owner Status: Current Owner
Purchase Date: 3/21/2011
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 11/13/2013

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/1/2011 12/31/2012

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007371 IDOT District #8 Current Owner 3/21/2011
U0033977 Raqqa, Inc. Former Owner 2/1/2007
U0031031 U.S.R.P. (St. Louis) L.L.C. Former Owner 11/18/2002
U0030745 USRP Funding 2002-A LP Former Owner 9/1/2001
U0034459 U.S. Restaurant Properties Former Owner 8/31/2001
U0029570 Marshall 66 St. Louis LLC Former Owner 7/1/2000
U0027672 Y'S Choice LLC Former Owner 7/22/1998
U0003073 Clark Retail Enterprises, Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
15-0919 8/19/2015 Removal Log 00762-2015REM
99-0276 2/8/1999 Removal Log 00284-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-0276 Eligible 10/21/2002 11/18/2002 $10,000
99-0276 Withdrawn 10/21/2002 10/21/2002 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/8/1999
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1999 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/8/1999
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/19/2015
OSFM First Notify Date: 6/1/1999 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 5/1/1999 Red Tag Issue Date:
Last Used Date: 4/3/2012 Fee Due: $0.00
Product Date: 5/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/10/2008 10/10/2011
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/26/2010 10/26/2011
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Ball Float Vent Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/19/2015
OSFM First Notify Date: 6/1/1999 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 5/1/2001 Red Tag Issue Date:
Last Used Date: 4/3/2012 Fee Due: $0.00
Product Date: 5/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/10/2008 10/10/2011
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/26/2010 10/26/2011
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Ball Float Vent Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found