Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6000366
Status: Closed
Facility Name: Circle K #1339
Address: 421 South Belt East
Belleville, IL 62221
County: St. Clair
Property Parcel: 08-27.0-311-022
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: U002030
Green Tag Issue Date: 10/21/2019
Green Tag Expiration Date: 3/26/2021

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 2/12/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/6/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/19/2019 12/31/2021

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 2/12/2013
U0004080 Dickerson Petroleum Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
09-1113 10/8/2009 Removal Log 00963-2009REM
2021-0196 3/24/2021 Removal Log 00250-2021REM
2021-0196 3/25/2021 Removal Log 00250-2021REM
2021-0196 3/31/2021 Removal Log 00378-2021REM
96-1319 7/23/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
04-1678 Eligible 12/21/2004 1/25/2005 $10,000
04-1678 Eligible 3/5/2013 4/3/2013 $10,000
20210196 Partial Eligible 5/6/2021 5/6/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2009
OSFM First Notify Date: 12/27/1985 Abandoned Material: Inert material mixed with portland cement
Current Age: 43 Abandoned Date: 4/19/2005
Install Date: 12/1/1965 Red Tag Issue Date:
Last Used Date: 11/17/2004 Fee Due: $0.00
Product Date: 12/1/1965

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2009
OSFM First Notify Date: 12/30/1985 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 12/1/1965 Red Tag Issue Date:
Last Used Date: 11/17/2004 Fee Due: $0.00
Product Date: 12/1/1965

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Piping Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Double Wall steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2009
OSFM First Notify Date: 12/27/1985 Abandoned Material: Inert material mixed with portland cement
Current Age: 43 Abandoned Date: 6/1/1991
Install Date: 12/1/1965 Red Tag Issue Date:
Last Used Date: 4/1/1991 Fee Due: $0.00
Product Date: 12/1/1965

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/24/2021
OSFM First Notify Date: 12/27/1985 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 10/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/26/2019 4/26/2022
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/11/2020 4/11/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/19/2020 11/19/2021
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 11/19/2020 11/19/2021
Overfill Prev Device Overfill Drop Tube Valve 12/6/2018 12/6/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/6/2018 12/6/2021
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 11/19/2020



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/24/2021
OSFM First Notify Date: 12/27/1985 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 10/11/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/11/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/26/2019 4/26/2022
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/11/2020 4/11/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/19/2020 11/19/2021
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 11/19/2020 11/19/2021
Overfill Prev Device Overfill Drop Tube Valve 12/6/2018 12/6/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/6/2018 12/6/2021
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 11/19/2020



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2009
OSFM First Notify Date: 12/27/1985 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 10/11/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/11/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Piping Double Wall steel N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 2000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 7/23/1996
OSFM First Notify Date: 3/13/1992 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1962 Red Tag Issue Date:
Last Used Date: 2/1/1995 Fee Due: $0.00
Product Date: 1/1/1962

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/25/2021
OSFM First Notify Date: 10/26/2009 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 10/14/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 10/29/2019 10/29/2022
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/11/2020 4/11/2023
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/19/2020 11/19/2021
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 11/19/2020 11/19/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/19/2020 11/19/2021
Overfill Prev Device Overfill Drop Tube Valve 9/6/2019 9/6/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/17/2019 5/17/2022
Leak Detect - Piping Sump Sensor 11/19/2020 11/19/2021
Piping Single Wall Transition Sump 5/17/2019 5/17/2022
Leak Detect - Piping Sump Sensor 11/19/2020 11/19/2021
Spill Contain Device Single Wall Spill Bucket 12/6/2018 12/6/2021
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 11/19/2020



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/25/2021
OSFM First Notify Date: 10/26/2009 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 10/14/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/26/2019 4/26/2022
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/19/2020 11/19/2021
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 11/19/2020 11/19/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/19/2020 11/19/2021
Overfill Prev Device Overfill Drop Tube Valve 4/1/2019 4/1/2022
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/17/2019 5/17/2022
Leak Detect - Piping Sump Sensor 11/19/2020 11/19/2021
Spill Contain Device Single Wall Spill Bucket 12/6/2018 12/6/2021
Tank Composite Double Wall Permatank N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 11/19/2020



Tank Number 10

Capacity: 1000 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 3/31/2021
OSFM First Notify Date: 3/30/2021 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 550 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 3/31/2021
OSFM First Notify Date: 3/30/2021 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found