Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5041297
Status: Active
Facility Name: Fas Mart #5137
Address: 1645 Wabash Avenue
Jerome, IL 62704
County: Sangamon
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000769
Green Tag Issue Date: 6/23/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: GPM Midwest, LLC
Owner Address: 8565 Magellan Pkwy, Ste. 400
Richmond, VA 23227
Owner Status: Current Owner
Purchase Date: 3/19/2015
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 4/14/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/23/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037728 GPM Midwest, LLC Current Owner 3/19/2015
U0023300 First Ranger Petroleum LLC Former Owner 10/17/2002
U0033990 Road Ranger, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/17/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 10/17/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/17/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2024 1/29/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Link 1/29/2024 1/29/2025
Overfill Prev Device Ball Float Vent Valve OPW 53V 1/14/2022 1/14/2025
Overfill Prev Device Overfill Alarm 1/14/2022 1/14/2025
Piping Flexible Double Wall OPW Pisces N/A N/A
Piping Single Wall STP/Tanktop Sump 3/27/2024 3/27/2027
Leak Detect - Piping Sump Sensor 1/29/2024 1/29/2025
Spill Contain Device Single Wall Spill Bucket 1/14/2022 1/14/2025
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Pisces Precision Test Fail 1/23/2024
Piping Flexible Double Wall OPW Pisces Precision Test Pass 2/5/2024



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/17/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 10/17/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/17/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2024 1/29/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Link 1/29/2024 1/29/2025
Overfill Prev Device Ball Float Vent Valve OPW 53V 1/14/2022 1/14/2025
Overfill Prev Device Overfill Alarm 1/14/2022 1/14/2025
Piping Flexible Double Wall OPW Pisces N/A N/A
Piping Single Wall STP/Tanktop Sump 3/27/2024 3/27/2027
Leak Detect - Piping Sump Sensor 1/29/2024 1/29/2025
Spill Contain Device Single Wall Spill Bucket 1/14/2022 1/14/2025
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Pisces Precision Test Pass 1/23/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/27/2024 3/27/2027
Leak Detect - Piping Sump Sensor 1/23/2024 1/23/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/27/2024 3/27/2027
Leak Detect - Piping Sump Sensor 1/23/2024 1/23/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/27/2024 3/27/2027
Leak Detect - Piping Sump Sensor 1/23/2024 1/23/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/27/2024 3/27/2027
Leak Detect - Piping Sump Sensor 1/23/2024 1/23/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms