Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5033172
Status: Active
Facility Name: AM PM Franklin, Inc. d/b/a Franklin Fast Stop
Address: 2930 Highway 104
Franklin, IL 62638
County: Morgan
Property Parcel: 14-36-207-019
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002310
Green Tag Issue Date: 8/21/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: AM PM Franklin, Inc.
Owner Address: 2930 State Hwy. 104
Franklin, IL 62638
Owner Status: Current Owner
Purchase Date: 8/5/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/7/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/21/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040039 AM PM Franklin, Inc. Current Owner 8/5/2020
U0013645 Prairieland FS, Inc. Former Owner 12/1/2013
U0004992 Lincoln Land FS, Inc. Former Owner 12/30/2010
U0032379 Flashes Junction, Inc. Former Owner 8/1/2002
U0008156 Junction Sales Inc. Former Owner 8/15/1994

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/2/1994 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/15/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/29/2024 2/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/29/2024 2/28/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/29/2024 2/28/2025
Overfill Prev Device Overfill Drop Tube Valve 6/20/2023 6/20/2026
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor 2/29/2024 2/28/2025
Spill Contain Device Single Wall Spill Bucket 6/20/2023 6/20/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test Pass 2/29/2024



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/2/1994 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/15/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/29/2024 2/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/29/2024 2/28/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/29/2024 2/28/2025
Overfill Prev Device Overfill Drop Tube Valve 6/20/2023 6/20/2026
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 7/12/2023 7/12/2026
Leak Detect - Piping Sump Sensor 2/29/2024 2/28/2025
Spill Contain Device Single Wall Spill Bucket 6/20/2023 6/20/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test Pass 2/29/2024



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/2/1994 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/15/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/29/2024 2/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/29/2024 2/28/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/29/2024 2/28/2025
Overfill Prev Device Overfill Drop Tube Valve 6/20/2023 6/20/2026
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 7/12/2023 7/12/2026
Leak Detect - Piping Sump Sensor 2/29/2024 2/28/2025
Spill Contain Device Single Wall Spill Bucket 3/1/2023 3/1/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test Pass 2/29/2024
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 4/3/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found