Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5020380
Status: Active
Facility Name: Illinois State Police Academy
Address: 3700 East Lake Shore Drive
Springfield, IL 62712
County: Sangamon
Property Parcel:
Facility Type: State
Owner Type: State
Green Tag Decal: Y004217
Green Tag Issue Date: 9/19/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Illinois State Police
Owner Address: 801 South 7th Street
Springfield, IL 62703
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/19/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007412 Illinois State Police Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/16/1999
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/21/1998 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 600 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/23/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 2/16/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/16/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Composite Secondary Containment N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 3/27/2024 3/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/27/2024 3/27/2025
Overfill Prev Device Overfill Alarm 3/16/2022 3/16/2025
Piping Composite Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/16/2022 3/16/2025
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms