Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5015800
Status: Closed
Facility Name: K.E. Vas Company
Address: 311 Moeller Road
Jacksonville, IL 62650
County: Morgan
Property Parcel:
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: V004732
Green Tag Issue Date: 11/17/2020
Green Tag Expiration Date: 2/2/2021

Owner Details

Owner Name: K.E. Vas Company
Owner Address: P.O. Box 190
Jacksonville, IL 62651
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 11/17/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 11/4/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008298 K.E. Vas Company Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2020-1081 1/6/2021 Removal Log 01782-2020REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20201081 Eligible 4/28/2021 5/6/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Dyed Diesel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/6/2021
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 4/22/1982 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 11/17/2020 11/17/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 8/13/2020 8/13/2021
Overfill Prev Device Overfill Drop Tube Valve 8/13/2020 8/13/2023
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/13/2020 8/13/2023
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 11/19/2020



Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/31/1987
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/7/2000
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 12/21/1998 Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/6/2021
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 3/26/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/24/2014 9/24/2019
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 with SCALD 8/13/2020 8/13/2021
Overfill Prev Device Overfill Drop Tube Valve 8/13/2020 8/13/2023
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/13/2020 8/13/2023
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID East Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID West Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found