Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5008870
Status: Active
Facility Name: Quincy College Corporation
Address: 1800 College Avenue
Quincy, IL 62301
County: Adams
Property Parcel:
Facility Type: School/College
Owner Type: Private
Green Tag Decal: Z003533
Green Tag Issue Date: 2/14/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Quincy University
Owner Address: 1800 College Avenue
Quincy, IL 62301
Owner Status: Current Owner
Purchase Date: 4/11/1999
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/15/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0012302 Quincy University Current Owner 4/11/1999

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 4/28/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 4/5/2024 4/5/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 4/5/2024 4/5/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 4/5/2024 4/5/2025
Overfill Prev Device Overfill Drop Tube Valve 5/2/2022 5/2/2025
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/18/2022 5/18/2025
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test Pass 1/21/2020
Tank Steel Single Wall Precision Test (Tank) Pass 1/21/2020



Tank Number 2

Capacity: 10000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 4/28/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 4/5/2024 4/5/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 4/5/2024 4/5/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 4/5/2024 4/5/2025
Overfill Prev Device Overfill Drop Tube Valve 5/2/2022 5/2/2025
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/18/2022 5/18/2025
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test Pass 1/21/2020
Tank Steel Single Wall Precision Test (Tank) Pass 1/21/2020



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/17/1997
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/17/1977 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found