Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4040840
Status: Active
Facility Name: Huck's #360
Address: 102 West Oakland Street
Bloomington, IL 61701
County: McLean
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X001211
Green Tag Issue Date: 2/7/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Martin & Bayley, Inc.
Owner Address: P.O. Box 385
Carmi, IL 62821
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 9/24/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/7/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009763 Martin & Bayley, Inc. Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01342-2023CAT Cathodic Protection Approved / Issued 11/21/2023 11/21/2023 5/21/2024 Documents

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/9/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/10/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Polyethylene Chase N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/13/2023 9/13/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2023 9/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/13/2023 9/13/2024
Overfill Prev Device Overfill Drop Tube Valve 1/27/2022 1/27/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/27/2022 1/27/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 10/28/2019
Piping Flexible Double Wall Precision Test Pass 9/13/2023
Piping Flexible Single Wall Piping in Chase Precision Test Pass 10/14/2021



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/9/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/10/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 11/29/2023 11/29/2026
Corrosion Prot - Piping Polyethylene Chase N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2023 9/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/13/2023 9/13/2024
Overfill Prev Device Overfill Drop Tube Valve 1/27/2022 1/27/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/14/2021 10/14/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 10/28/2019
Piping Flexible Double Wall Precision Test Pass 9/13/2023
Piping Flexible Single Wall Piping in Chase Precision Test Pass 10/14/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 6/17/2020



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/9/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/10/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Polyethylene Chase N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/13/2023 9/13/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2023 9/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/13/2023 9/13/2024
Overfill Prev Device Overfill Drop Tube Valve 1/27/2022 1/27/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/14/2021 10/14/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 9/13/2023
Piping Flexible Double Wall Precision Test Pass 10/28/2019
Piping Flexible Single Wall Piping in Chase Precision Test Pass 10/14/2021



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/9/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/10/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/28/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Polyethylene Chase N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/13/2023 9/13/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2023 9/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/13/2023 9/13/2024
Overfill Prev Device Overfill Drop Tube Valve 1/27/2022 1/27/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/27/2022 1/27/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 9/13/2023
Piping Flexible Double Wall Precision Test Pass 10/28/2019
Piping Flexible Single Wall Piping in Chase Precision Test Pass 10/14/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found