Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4038852
Status: Active
Facility Name: Dayton Freight Lines
Address: 945 Bob King Drive
Arcola, IL 61910
County: Douglas
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: X003888
Green Tag Issue Date: 5/24/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Stream's Edge Properties, LLC
Owner Address: 6450 Poe Ave., Suite 311
Dayton, OH 45414
Owner Status: Current Owner
Purchase Date: 9/20/2009
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/20/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 5/24/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035869 Stream's Edge Properties, LLC Current Owner 9/20/2009
U0022799 FedEx Freight East, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/4/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 7/12/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/12/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/25/2023 7/25/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/25/2023 7/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/25/2023 7/25/2024
Overfill Prev Device Overfill Alarm 7/25/2023 7/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/25/2023 7/25/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/31/2021 8/31/2024
Leak Detect - Piping Sump Sensor 7/25/2023 7/25/2024
Spill Contain Device Single Wall Spill Bucket 8/31/2021 8/31/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 7/25/2023

Dispenser Information



Name\ID 1 MAIN

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/31/2021 8/31/2024
Leak Detect - Piping Sump Sensor 7/25/2023 7/25/2024

MFD Motorfuel Dispensing Forms

No Forms Found