Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4038834
Status: Active
Facility Name: Pilot Travel Center #165
Address: 2500 North 3rd Street
Effingham, IL 62401
County: Effingham
Property Parcel: 03-11-009-030
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002564
Green Tag Issue Date: 11/7/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Pilot Travel Centers, LLC
Owner Address: 5508 Lonas Rd.
Knoxville, TN 37909
Owner Status: Current Owner
Purchase Date: 4/19/2001
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/24/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/25/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011913 Pilot Travel Centers, LLC Current Owner 4/19/2001

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
03-1303 Eligible 3/16/2004 3/24/2004 $10,000
09-0241 Eligible 4/30/2009 5/19/2009 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 53VML
Piping Fiberglass Double Wall Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 8/1/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/13/2023 11/13/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/14/2023 11/14/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 11/13/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 3/4/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 3/1/2008



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 8/1/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/11/2022 8/11/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/13/2023 11/13/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/14/2023 11/14/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 11/13/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 3/4/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 3/1/2008



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 8/1/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/13/2023 11/13/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/13/2023 11/13/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/14/2023 11/14/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/21/2022 10/21/2025
Leak Detect - Piping Sump Sensor 11/13/2023 11/13/2024
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 11/13/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 10/21/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 3/1/2008



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 8/1/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/13/2023 11/13/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/14/2023 11/14/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/21/2022 10/21/2025
Leak Detect - Piping Sump Sensor 11/13/2023 11/13/2024
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 11/13/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 10/21/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 3/1/2008



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/8/2006 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: 5/25/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/25/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/14/2023 11/14/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/21/2022 10/21/2025
Leak Detect - Piping Sump Sensor 11/13/2023 11/13/2024
Piping Single Wall Transition Sump 10/21/2022 10/21/2025
Leak Detect - Piping Sump Sensor 11/13/2023 11/13/2024
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 3/4/2021
Tank Fiberglass Double Wall Precision Test (Tank) Pass 3/4/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 3/1/2008
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 3/1/2008



Tank Number 7

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/28/2010 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/8/2009 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 7/8/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/13/2023 11/13/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/28/2023 11/28/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/21/2022 10/21/2025
Leak Detect - Piping Sump Sensor 11/13/2023 11/13/2024
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 11/13/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/4/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 7/8/2009
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 7/8/2009



Tank Number 8

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/28/2010 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/8/2009 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 7/8/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/13/2023 11/13/2024
Overfill Prev Device Overfill Drop Tube Valve 11/28/2023 11/28/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/27/2019 7/27/2022
Leak Detect - Piping Non-Discriminating Sump Sensor 2/17/2022 2/17/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/8/2022 5/8/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 11/13/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/4/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 7/8/2009
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 7/8/2009



Tank Number 9

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Entered in error CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 17sat

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/21/2022 10/21/2025
Leak Detect - Piping Sump Sensor 11/13/2023 11/13/2024



Name\ID 18/19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 20/21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 22/23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 24m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found