Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4034512
Status: Active
Facility Name: Ironwood Golf Course Maintenance Building
Address: 1901 N. Towanda Avenue
Normal, IL 61761
County: McLean
Property Parcel:
Facility Type: Golf Course
Owner Type: Municipal
Green Tag Decal: X002737
Green Tag Issue Date: 10/13/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Town of Normal
Owner Address: 100 E. Phoenix Ave.
Normal, IL 61761
Owner Status: Current Owner
Purchase Date: 9/15/1995
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 9/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/13/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0003032 Town of Normal Current Owner 9/15/1995

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1995 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 9/15/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/6/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Chase Secondary Containment Farm Pump N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 9/22/2023 9/22/2024
Overfill Prev Device Overfill Alarm 10/12/2021 10/12/2024
Piping Steel Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/21/2021 9/21/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1995 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 9/15/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/6/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Chase Secondary Containment Farm Pump N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 9/22/2023 9/22/2024
Overfill Prev Device Overfill Alarm 10/12/2021 10/12/2024
Piping Steel Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/21/2021 9/21/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found