Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4029967
Status: Active
Facility Name: Ryder Transportation Services #0669C
Address: 2001 Eagle Road
Normal, IL 61761
County: McLean
Property Parcel: 14-16-100-028
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: X002329
Green Tag Issue Date: 6/28/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Ryder Truck Rental, Inc.
Owner Address: 757 N. Eldridge Parkway
Suite 760
Houston, TX 77079
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/3/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 6/28/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013289 Ryder Truck Rental, Inc. Current Owner
U0013290 Ryder Truck Rental Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 5/23/2023 Removal Log 00282-2023REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/23/2023
OSFM First Notify Date: 4/16/1992 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 11/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/16/2023 2/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/16/2023 2/16/2024
Overfill Prev Device Overfill Drop Tube Valve 2/16/2023 2/16/2026
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 4/7/2021 4/7/2024
Leak Detect - Piping Sump Sensor 2/16/2023 2/16/2024
Spill Contain Device Single Wall Spill Bucket 3/11/2021 3/11/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 2/16/2023



Tank Number 2

Capacity: 15000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/10/2023 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 6/7/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/28/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/2/2024 2/2/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 2/2/2024 2/2/2025
Overfill Prev Device Overfill Alarm 2/7/2024 2/7/2027
Overfill Prev Device Overfill Drop Tube Valve 2/2/2024 2/2/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/6/2024 3/6/2027
Leak Detect - Piping Sump Sensor with positive shutdown 2/2/2024 2/2/2025
Spill Contain Device Double Wall Spill Bucket 2/2/2024 2/2/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 2/2/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 8/11/2023

Dispenser Information



Name\ID 5/6M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/6/2024 3/6/2027
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/6/2024 3/6/2027
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 6S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/6/2024 3/6/2027
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
4029967 Ryder Transportation Services #0669C Normal 08/08/2023 Letter Form